SERVICE (cont.)
START SWITCH
If continuity is present as described, reconnect the wires, the switch is operating properly.
If continuity is not present as described, replace the switch.
Removal and Replacement:
1.Remove the wires from the switch terminals.
2.Compress the clips inside the hood and gently push the switch through the opening.
3.Push the new switch into the opening and spread the clips to hold the switch captive in the hood.
4.Refer to Fig. 18 when reconnecting the wires.
P1833.40 |
FIG. 17 START SWITCH |
Location:
GRN to Dilution Timer TL5
RED/BLK to Dilution Timer TL3
WHI/YEL to Brew Timer TL5
WHI/ORN to Brew Timer TL3
The start switch is located in the right front of the hood.
Test Procedure:
1.Disconnect the brewer from the power source.
2.Remove the wires from all four terminals.
3.Check for continuity across the two terminals on the right side of the switch when it is held in the lower position. Continuity must not be present across these terminals in the upper position.
If continuity is present as described, proceed to #4. If continuity is not present as described, replace the switch.
4.Check for continuity across the two terminals on the left side of the switch when it is held in the lower position. Continuity must not be present across these terminals in the upper position.
FIG. 18 START SWITCH TERMINALS
P1283
Page 26 | 10145 | 072600 |
|
|