Bunn U3/SRU service manual Electrical Requirements - Sru, Srua, Ce Requirements

Models: U3/SRU

1 9
Download 9 pages 14.77 Kb
Page 5
Image 5
ELECTRICAL REQUIREMENTS - SRU, SRUA

ELECTRICAL REQUIREMENTS - SRU, SRUA

CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.

BLACK L1

RED

230V A.C.

L2

GREEN

GREEN

 

P1842

SRUA-CEModelsrequire2-wire, grounded service rated 230 volts ac, 30 amp, single phase, 50 Hz.

BLACK L1

208 OR

 

RED

L2

240V A.C.

 

 

GREEN

 

GREEN

 

 

P1842

SRU Models require 2-wire, grounded service rated 208 or 240 volts ac, 30 amp, single phase, 60 Hz.

CE REQUIREMENTS

This appliance must be installed in locations where it can be overseen by trained personnel.

For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.

Appliance shall not be tilted more than 10° for safe operation.

An electrician must provide electrical service as specified in conformance with all local and national codes.

This appliance must not be cleaned by water jet.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of this appliance by a person responsible for its safety.

Children should be supervised to ensure they do not play with the appliance.

• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.

ELECTRICAL INSTALLATION INSTRUCTIONS - ALL MODELS

NOTE: Electrical source should have a circuit breaker between the brewer and the main supply which breaks all poles with a contact separation of at least 3 mm.

CAUTION – Improper electrical installation will damage electronic components.

1.An electrician must provide electrical service as specified.

2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

3.Before electrically connecting the brewer, remove the front cupola cover (some models have the thermostat knob on the outside of the cover) and rotate the thermostat knob fully counterclockwise to the "OFF" position. Keep this knob in the "OFF" position until performing the Initial Setup.

4.Electrical service is connected at the upper rear of the single service and scrambler brewers using a junc- tion box. On double service brewers the rear decorative channel must be removed for access to the terminal block.

5.Connect the brewer to the power source and verify the voltage at the terminal block before proceeding. Re- place all panels.

6.If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing has been hooked up, the brewer is ready for Initial Setup.

Page 5

42769

012610

 

Page 5
Image 5
Bunn U3/SRU Electrical Requirements - Sru, Srua, Ce Requirements, Electrical Installation Instructions - All Models