Bunn VP17 manual SERVICE cont CONTROL THERMOSTAT

Models: VP17

1 16
Download 16 pages 365 b
Page 4
Image 4
SERVICE (cont.)

SERVICE (cont.)

CONTROL THERMOSTAT

P1161.40

FIG. 2 CONTROL THERMOSTAT

Location:

The control thermostat is located inside the trunk on the left side of the component bracket.

Test Procedures:

1.Disconnect the brewer from the power source.

2.With a voltmeter, check the voltage across the blue wire on the control thermostat and the white wire on the tank heater. Connect the brewer to the power source. The indication must be:

a)100 volts ac for two wire 100 volt models.

b)120 volts ac for two wire 120 volt models.

3.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4.

If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring harness.

4.Gently remove the capillary bulb and grommet from the tank.

5.With a voltmeter, check the voltage across the black wire of the control thermostat and the white wire on the tank heater when the control thermostat is turned "ON" (Fully clockwise). Connect the brewer to the power source. The indication must be:

a)100 volts ac for two wire 100 volt models.

b)120 volts ac for two wire 120 volt models.

6.Voltage must not be present when the thermostat is turned to the "OFF" position.

7. Disconnect the brewer from the power source.

If voltage is present as described, reinstall the capillary tube into the tank to the line 4.5" above the bulb, the control thermostat is operating properly.

If voltage is not present as described, replace the thermostat.

Removal and Replacement:

1.Remove wires from control thermostat leads.

2.Remove the thermostat capillary bulb by firmly pulling up on the capillary at the tank lid. This will disengage the grommet from the tank lid.

3.Remove the one #8-32 screw securing the con- trol thermostat to the component bracket in the trunk.

4.Slide the grommet to the line 4.5" above the bulb on the new capillary tube.

5.Insert the capillary bulb through the hole in the tank lid and press the grommet firmly and evenly so that the groove in the grommet fits into the tank lid.

6.Carefully bend the capillary tube so that the tube and bulb inside the tank are in the vertical posi- tion.

NOTE - The capillary tube must be clear of any electri- cal termination and not kinked.

7.Using one #8-32 screw secure the control thermo- stat to the component bracket inside the trunk.

8.Refer to Fig. 3 when reconnecting the wires.

9.Adjust the control thermostat as required.

Manual background BLU to BLU Lead from

Limit Thermostat

BLK to BLK Lead from

Tank Heater

P1263

FIG. 3 CONTROL THERMOSTAT TERMINALS

Page 4

46721

052512

 

Page 4
Image 4
Bunn VP17 manual SERVICE cont CONTROL THERMOSTAT