SERVICE (cont.)

LIMIT THERMOSTAT

P1161.40

FIG. 4 LIMIT THERMOSTAT

Location:

The limit thermostat is located inside the rear of the hood on the tank lid.

Test Procedures:

1.Disconnect the brewer from the power source.

2.Disconnect the blue and black wires from the limit thermostat.

3.With an ohmmeter, check for continuity across the limit thermostat terminals.

If continuity is present as described, the limit thermostat is operating properly.

If continuity is not present as described, replace the limit thermostat.

Removal and Replacement:

1.Remove all wires from limit thermostat termi- nals.

2.Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat.

3.Carefully slide the new limit thermostat into the retaining clip.

4.Refer to Fig. 5 when reconnecting the wires.

BLU to BLU Lead from

Control Thermostat

BLK to Terminal Block or Tank Heater Switch

P1800

FIG. 5 LIMIT THERMOSTAT TERMINALS

Page 5

46721

052512

 

Page 5
Image 5
Bunn VP17 manual Limit Thermostat