Burnham LEDV SERIES manual VII. System Start-up, Alwaysinspectinstallationbefore Starting Burner

Models: LEDV SERIES

1 36
Download 36 pages 34.46 Kb
Page 22
Image 22

VII. System Start-up

WARNING

All boilers equipped with burner swing door have a potential hazard w hich can cause severe property damage, personal injury or loss of life if ignored. Before opening swing door, turn off service switch to boiler to prevent accidental firing of burner outside the combustion chamber. Be sure to tighten swing door fastener completely when service is completed.

A.ALWAYSINSPECTINSTALLATIONBEFORE STARTING BURNER.

B. FILL HEATING SYSTEM WITH WATER. Refer to Section III, G.

C.CHECK CONTROLS, WIRING AND BURNER to be sure that all connections are tight and burner is rigid, that all electrical connections have been completed and fuses installed, and that oil tank is filled and oil lines have been tested.

D. LUBRICATION — Follow instruction on burner and circulator label to lubricate, if oil lubricated. Most motors currently used on residential type burners employ permanently lubricated bearings and thus do not require any field lubrication. Water lubricated circulators do not need field lubrication.

Do not over-lubricate. This can cause as much trouble as no lubrication at all.

E. SET CONTROLS with burner service switch turned “OFF”.

1.SET ROOM THERMOSTAT about 10° above room temperature.

2.PRESS RED RESET BUTTON on R8184P Oil Primary Control and release.

3.Set high limit dial on L8148 at temperature to suit requirements of installation.

F. BURNERSTART-UP

1.VERIFY burner settings. a. Refer to Table 4.

2.Open all shut-off valves in the oil supply line to the burner.

3.Attach a plastic hose to fuel pump vent fitting and provide a container to catch the oil.

4.REMOVE GAUGE PORT PLUG from fuel pump and install pressure gauge.

5.REMOVE TEST PLUG IN FLUE COLLAR.

6.Close the service switch to start the burner. If the burner does not start immediately, check the manual overload switch on the motor, if so equipped, and the safety switch of the burner primary control.

TABLE 4: BE CKETT AFII BURNER

Boiler

Firing Rate

 

Air Tube

 

 

Settings

 

Burner

Delavan Nozzle

 

 

 

 

A ir

Head

 

Pump Pressu re

Model

(GPH)

Combination

 

 

 

 

 

 

 

(stop screw)

 

(PSIG)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEDV -1

0.60

AFII 85

HLX50HD

0.50 x 70°B

2.5

#2

 

140

 

 

 

 

 

 

 

 

 

LEDV -2

1.00

AFII 150

HLX5 0HE

0.85 x 60°B

3.5

#3

 

140

 

 

 

 

 

 

 

 

 

LEDV -3

1.25

AFII 150

HLX5 0HE

1.00 x 60°B

4.0

#5

 

140

 

 

 

 

 

 

 

 

 

22

Page 22
Image 22
Burnham LEDV SERIES manual VII. System Start-up, Alwaysinspectinstallationbefore Starting Burner, Burnerstart-Up

LEDV SERIES specifications

The Burnham LEDV Series is a cutting-edge range of LED lighting solutions designed to meet the diverse needs of commercial and industrial applications. This series stands out for its exceptional energy efficiency, robust build quality, and innovative technology. With a focus on reducing carbon footprints and energy costs, the LEDV Series is a practical choice for forward-thinking businesses and organizations.

One of the main features of the Burnham LEDV Series is its impressive energy efficiency. Utilizing advanced LED technology, these fixtures consume significantly less power than traditional lighting systems, leading to substantial savings on electricity bills. Coupled with a long operational lifespan, often exceeding 50,000 hours, the LEDV Series reduces the frequency and costs associated with replacements and maintenance.

The design of the LEDV fixtures emphasizes versatility, making them suitable for a variety of settings. From warehouses to office buildings, retail spaces, and outdoor environments, these lights provide exceptional illumination tailored to specific application requirements. The series includes options for various mounting configurations, allowing for easy installation and customization based on the unique layout of a space.

One of the standout technologies integrated into the LEDV Series is the intelligent dimming capability. This feature allows users to adjust the brightness of the lighting based on occupancy or ambient light levels, further enhancing energy savings. In addition, some models are compatible with smart building systems, enabling centralized control and monitoring through mobile applications or integrated building management systems.

Moreover, the Burnham LEDV Series is designed with durability in mind. With a robust housing constructed from high-quality materials, these lighting solutions are resistant to harsh environmental conditions. Many models feature impact-resistant designs and high ingress protection ratings, making them ideal for use in tough industrial settings or outdoor environments.

Another key characteristic of the LEDV Series is the emphasis on quality of light. The fixtures provide excellent color rendering, which is essential for ensuring that colors appear natural and true within any given space. This feature is particularly important in retail environments where product appearance can significantly influence purchasing decisions.

In summary, the Burnham LEDV Series combines energy efficiency, innovative technology, and superior durability to deliver a lighting solution that meets the demands of modern applications. With features like intelligent dimming, versatile design, and high-quality light output, these fixtures are an investment in sustainability and operational excellence.