I. Pre-Installation

A. INSPECT SHIPMENT carefully for any signs of damage.

1.ALL EQUIPMENT is carefully manufactured, inspected and packed. Our responsibility ceases upon delivery of crated boiler to the carrier in good condition.

2.ANY CLAIMS for damage or shortage in shipment must be filed immediately against the carrier by the consignee. No claims for variances from, or shortage in orders, will be allowed by the manufacturer unless presented within sixty (60) days after receipt of goods.

B. LOCATE BOILER in front of final position before removing crate. See Figure 1. Boiler's approximate shipping weight is 325 pounds.

1.LOCATE so that vent pipe will be short and direct. Refer to Section V. A., General Venting Guidelines.

2.BOILERISSUITABLEFORINSTALLATIONON COMBUSTIBLE FLOOR. Boiler cannot be installed on carpeting.

3.FOR BASEMENT INSTALLATION, provide a solid base, such as concrete, if floor is not level, or if water may be encountered on floor around boiler.

4.PROVIDE SERVICE CLEARANCE of at least 24” at front of boiler for servicing.

5.For minimum clearances to combustible materials, see Figure 2.

C. PROVIDECOMBUSTIONAIRSUPPLYto accommodate proper combustion of oil. Local and national codes may apply and should be referenced.

1.In unconfined spaces (basement) in buildings of conventional frame, brick, or stone construction, infiltration normally is adequate to provide air for combustion. An unconfined space is a space whose volume is greater than or equal to 50 cubic feet per 1000 BTUH of the combined input of all air consuming appliances in the space.

2.In a confined space, combustion air may be ducted directly from the outdoors to the burner. Refer to Section IV for installation of air intake duct to the burner.

D. VENTILATION AIR must be provided to maintain the ambient temperature at safe limits. Local and national codes may apply and should be referenced.

1.In unconfined spaces (basement) in buildings of conventional frame, brick, or stone construction, infiltration normally is adequate to provide air for ventilation.

2.In confined spaces (closet, etc.) two permanent openings, one near the top of the enclosure and one near the bottom, shall be provided. Each opening shall have a free area of not less than 1 sq. inch per 1000 BTUH of the total input of all appliances in the space.

E. Do not install boiler where gasoline or other flammable vapors or liquids, or sources of hydrocarbons (i.e. bleaches, cleaners, chemicals, sprays, paint removers, fabric softeners, etc.) are used or stored.

6

Page 6
Image 6
Burnham LEDV SERIES manual Pre-Installation

LEDV SERIES specifications

The Burnham LEDV Series is a cutting-edge range of LED lighting solutions designed to meet the diverse needs of commercial and industrial applications. This series stands out for its exceptional energy efficiency, robust build quality, and innovative technology. With a focus on reducing carbon footprints and energy costs, the LEDV Series is a practical choice for forward-thinking businesses and organizations.

One of the main features of the Burnham LEDV Series is its impressive energy efficiency. Utilizing advanced LED technology, these fixtures consume significantly less power than traditional lighting systems, leading to substantial savings on electricity bills. Coupled with a long operational lifespan, often exceeding 50,000 hours, the LEDV Series reduces the frequency and costs associated with replacements and maintenance.

The design of the LEDV fixtures emphasizes versatility, making them suitable for a variety of settings. From warehouses to office buildings, retail spaces, and outdoor environments, these lights provide exceptional illumination tailored to specific application requirements. The series includes options for various mounting configurations, allowing for easy installation and customization based on the unique layout of a space.

One of the standout technologies integrated into the LEDV Series is the intelligent dimming capability. This feature allows users to adjust the brightness of the lighting based on occupancy or ambient light levels, further enhancing energy savings. In addition, some models are compatible with smart building systems, enabling centralized control and monitoring through mobile applications or integrated building management systems.

Moreover, the Burnham LEDV Series is designed with durability in mind. With a robust housing constructed from high-quality materials, these lighting solutions are resistant to harsh environmental conditions. Many models feature impact-resistant designs and high ingress protection ratings, making them ideal for use in tough industrial settings or outdoor environments.

Another key characteristic of the LEDV Series is the emphasis on quality of light. The fixtures provide excellent color rendering, which is essential for ensuring that colors appear natural and true within any given space. This feature is particularly important in retail environments where product appearance can significantly influence purchasing decisions.

In summary, the Burnham LEDV Series combines energy efficiency, innovative technology, and superior durability to deliver a lighting solution that meets the demands of modern applications. With features like intelligent dimming, versatile design, and high-quality light output, these fixtures are an investment in sustainability and operational excellence.