Whirlpool E1F12US015V, E2F50HD045V, E2F65HD045V Electrical Requirements, Electric Shock Hazard

Models: 140389 140449 121802 E1F50RD045V 140426 140452 140378 E1F20US015V 120V 6510413 140385 140422 140425 E2F50LD045V E2F30HD035V 140403 E2F80HD045V W10123243 E2F50HD045V E2F30LD035V E2F40RD045V E1F12US015V E2F65HD045V E2F40LD045V E2F40HD045V

1 16
Download 16 pages 19.49 Kb
Page 5
Image 5
Electrical Requirements

Electrical Requirements

Electric Shock HazardWARNING

Electric Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

Disconnect power before servicing.WARNING

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL listed or

CSA approved strain relief.

Connect ground wire to green ground screw.

Failure to do so can result in death, fire, or electrical shock.

If you lack the necessary skills required to properly install the electrical wiring to this water heater, do not proceed but have a qualifi ed electrician perform the installation.

When making the electrical connections, always make sure:

The electrical supply has the proper overload fuse or breaker protection.

Wire sizes and connections comply with all applicable codes.

Wiring enclosed in approved conduit (if required by local codes).

The water heater and electrical supply are properly grounded.

Figures 3, 4, and 5 are provided as reference drawings for the 120/240v 2-wire models only. Always reference the wiring diagram located on the water heater for the

Figure 2

Heating Element

NOTE: Applying electrical power to elements that are not submerged in water will destroy them. The manufacturer will not warranty any elements damaged in this manner.

Figure 3

 

 

 

 

120/240V 2-Wire Models

 

 

 

Junction Box

Green

Ground

 

Wire

 

Ground

Conduit

Cover

 

 

 

 

Screw

 

 

 

White Wire (120V Models)

Black Wire

 

 

Red Wire (240V Models)

 

 

 

 

Figure 4

Wiring Diagram

120V Models Only Overload Circuit

Protection

Breaker

Approved Connectors

Black

Hot

White

To 120V

Power Supply

 

Neutral

 

Ground

 

Screw

 

Electrical

 

Service Ground

Figure 5

Wiring Diagram

208/240v Models Only

Overload

Protection Circuit

Breaker

Approved Connectors

correct electrical connections and connect the electrical supply to the water heater in accordance with local utility requirements and codes.

When installing the electrical wiring to the water heater:

1.Be sure tank is completely filled with water before making any electrical connections. (See Figure 2)

2.Disconnect the electric power.

3.Loosen the screw holding the junction box cover to the top of the water heater and set aside.

4.Connect the electrical supply to the water heater. A standard 1/2 inch opening has been made in the junction box for conduit connections.

5.Connect ground wire to green ground screw in the junction box of the water heater. Reinstall the junction box cover.

Black

Red

Ground

Screw

Electrical

Service ground

L1

L2

To 208/240v

1Phase Power supply

5

Page 5
Image 5
Whirlpool E1F12US015V, E2F50HD045V Electrical Requirements, Electric Shock Hazard, Disconnect power before servicing