FOR ANY REPAIRS OR ADJUSTMENTS – OTHER THAN THOSE DETAILED IN THIS MANUAL – PLEASE CONTACT
8. Care and Maintenance
Every attempt has been made to make this exceptionally powerful tool both reliable and
•Make sure that the applicator is up to temperature before attempting to operate.
•Do not leave the applicator switched on for long periods without use. If the applicator is not to be used for forty minutes or more, switch it off and restart when required.
•Keep the applicator upright when not in use, never lay it on its side. Always use the stand provided, or the optional bench stand or suspension unit (see Spares and Accessory lists at the end of this manual).
•Do not use excessive force on the trigger. Ensure that the tool has fully warmed up before use.
•Keep the nozzle clean to prevent adhesive
9.Accessories and Spare Parts
Spare Parts | Part Number |
Complete Nozzle Assembly – Wide Angle 2mm | 985122 |
(fitted as standard) |
|
Applicator Stand | 985069 |
Barrel PTFE | 985071 |
Barrel Support Assembly | 985091 |
Piston Support Assembly | 985093 |
Piston | 985095 |
Thermostat Assembly, 180°C | 985123 |
Thermostat Assembly, 195°C (for polyamides) | 985079 |
Heater Assembly 120 Volts | 985080 |
PCB Assembly | 985083 |
Thermal Fuse, Spacer Assembly | 985076 |
Valve Body Airline Adapter | 985240 |
Heater Housing Kit For 98037 (EVA Adhesive) | 985232 |
Qty 1 – |
|
Qty 1 – Heater Housing, item 6 |
|
Qty 1 – Fitting, item 30 |
|
Qty 1 – Ground Screw, item 38 |
|
Qty 1 - Lock Washer, item 42 |
|
Heater Housing Kit For 98041 (Polyamides Adhesives) | 985239 |
Qty 1 – |
|
Qty 1 – Heater Housing, item 47 |
|
Qty 1 – Fitting, item 30 |
|
Qty 1 – Ground Screw, item 38 |
|
Qty 1 - Lock Washer, item 42 |
|
Handle Kit | 985228 |
Qty 2 – Moulded handles, item 1 |
|
Qty 6 – Casing Screws, item 37 |
|
Piston Support Hardware Kit | 985229 |
Qty 1 – Washer, special with 4 holes, item 33 |
|
Page 6