LP Gas

Tank Requirements

For plumbed-in LP installation, use a convertible regulator and set it for LP gas.

Maximum line pressure for plumbed-in propane is 14” WC (3.5 kPa). Minimum line pressure for propane is 11” WC.

The Power Burner must be used with the gas pressure regulator. The regulator will control and maintain a uniform gas pressure in the mani- fold. The burner orifices have been sized for the gas pressure delivered by the regulator.

WARNING: Attempting to operate the Power Burner without the gas regulator installed could cause an explosion and possible death.

Cylinder Specification

Any LP gas supply cylinder used with the Power Burner must be:

Constructed and marked in accordance with the Specifications for LP-Gas Cylinders of the U.S. Department of Transportation or the National Standard of Canada, CAN/CSA-B339, Cylin- ders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable.

Approximately 12 inches in diameter and 18 inches high.