Cal Flame LTR20081044 manual Leak Testing Procedure, Liquid Propane Gas, Tank Requirements

Models: LTR20081044

1 20
Download 20 pages 59.08 Kb
Page 6
Image 6

Installation / Assembly

Model Number

Description

Width

Depth

Height

Cut-out for drop in accessories

BBQ08852U

Drop In Standard Side

29.2 cm

45.1 cm

7.0 cm

 

 

 

Burner

 

 

 

 

DEPTH

BBQ08953U

Standard Side by Side

61.6 cm

50.2 cm

10.8 cm

WIDTH

 

 

 

 

Burner

 

 

 

HEIGHT

 

 

 

 

 

 

BBQ08954U

Deluxe Side by Side

64.1 cm

33.7cm

18.4 cm

 

 

 

 

Burner

 

 

 

 

 

 

 

 

 

 

 

 

Leak Testing Procedure

Perform a leak test at least once a year whether the gas supply has been disconnected or not. In addition, whenever the gas supply is connected to the regulator or whenever any part of the gas system is disconnected or replaced, perform a leak test.

As a safety precaution, remember to always leak test your grill outdoors in a well-ventilated area. Never smoke or permit sources of ignition in the area while doing a leak test. Do not use a flame, such as a lighted match to test for leaks. Use a solution of soapy water.

1.Prepare a leak testing solution of soapy water by mixing in a spray bottle one part liquid soap to one part water.

2.Make sure all the control knobs are in the OFF po- sition.

3.Turn on the gas. Turn the gas supply valve counter clockwise one turn to open.

If you are unable to stop a leak:

1.Turn all control knobs back to the full OFF posi- tion.

2.Shut off the gas supply to the grill and release pressure in the hose and manifold by pushing in and turning any of the control valves one quarter turn counter-clockwise.

3.Call an authorized gas appliance service techni- cian.

Do not use the appliance until the leak is corrected.

4.Apply the leak-testing solution by spraying it on joints of the gas delivery system. Blowing bubbles in the soap solution indicates that a leak is pres- ent.

5.Stop a leak by tightening the loose joint or by re- placing the faulty part with a replacement part rec- ommended by the manufacturer.

6.Turn all control knobs back to the full OFF posi- tion.

Liquid Propane Gas

Tank Requirements

For plumbed-in LP installation, use a convertible regu- lator and set it for LP gas.

Maximum line pressure for plumbed-in propane is 14” WC (3.5 kPa). Minimum line pressure for propane is 11” WC.

Page 4

Cal Flame 2008 Owner’s Manual

LTR20081044, Rev. A

Page 6
Image 6
Cal Flame LTR20081044 manual Leak Testing Procedure, Liquid Propane Gas, Tank Requirements