Operating Your Spa
turns on automatically, it cannot be deactivated from the panel; however, the high speed may be started.
Option (Optional Blower)
Press the OPTION button to turn the optional equipment on and off. If left on, the equipment will automatically turn off after 15 minutes.
Light
Press the LIGHT button to turn the spa light on and off.
Invert
Press the INVERT button to change the numbers in the display to read upside down. Another press returns the display to the
Locking the Panel
To lock the panel:
Press TIME, JETS 1, and the UP button within three seconds. When locked, the panel will display “LOCK”. All buttons are frozen except the TIME button.
To unlock the panel:
Press TIME, JETS ,1 then the DOWN button within three seconds.
Setting the Temperature Lock
To activate the temperature lock:
Press the UP or DOWN button, TIME, JETS 1, then the UP button within three seconds. The panel will display “TEMP LOCK” when the set temperature is locked.
To unlock the set temperature:
Press the UP or DOWN button, TIME, JETS 1, then the DOWN button..
Circulation Pump (optional)
If your system is equipped with a circulation pump, it may be configured to work in one of two different ways:
1.The circulation pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a time when the water temperature reaches 1.7˚C above the set temperature (most likely to happen in very hot climates).
2.The circulation pump will come on when the system is checking temperature, during filter cycles, during freeze conditions, or when another pump is on.
Preset Filter Cycles
There are two filter cycles per day. The start and end times of each cycle are programmable. To program, set the time as instructed above, then press MODE/PROG to advance to the next setting (or to exit after the last setting). The default filter cycles are as follows:
•The first filter cycle is automatically activated at 8:00
AM and operates the pump until 10:00 AM. The
“FILTER 1” indicator icon will light when filter 1 is running.
•The second filter cycle is automatically activated at
8:00 PM and operates the pump until 10:00 PM. The
“FILTER 2” indicator icon will light when filter 2 is running.
The pump and the ozone generator will run during filtration. At the start of each filter cycle, the blower will run on highest speed for 30 seconds to clean out the air channels. The lowest speed of pump 2 and pump 3 will run for five minutes. In the event of power loss or shut down, the time of day will need to be reset for filter cycles to run according to your desired programming.
Clean-up Cycle
When the pump or blower is turned on by a button press, a
Ozone (optional)
On most systems, the ozone generator (if installed) runs during filter cycles (except when pump 1 is operating at high speed on a
Freeze Protection
If the temperature sensors detect a drop to 6.7˚C within the heater, the pump automatically activates to provide freeze protection. The equipment stays on until four minutes after the sensors detect that the spa temperature has risen to 7.2˚C or higher. In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a four minute delay in turnoff.
Page 16 | 2009 Portable Spa Owner’s Manual |
LTR20091001, Rev. A