Operating Your Spa
Periodic Reminder Messages
Press the “Mode” button to reset a displayed reminder)
Message | Frequency | Action Required |
rPH | Every 7 days | Test and adjust chemical levels per manufacturer’s instructions. |
rSA | Every 7 days | Test and adjust chemical levels per manufacturer’s instructions. |
rCL | Every 30 days | Remove, clean, and reinstall filter per manufacturer’s instructions. |
rtg | Every 30 days | Test & reset GFCI per manufacturer’s instructions. Drain and refill spa per |
|
| manufacturer’s instructions. |
rdr | Every 90 days | Drain and refill spa per manufacturer’s instructions. |
RCO | Every 180 days | Clean and condition spa cover |
RCH | Every 365 days | Install New |
Diagnostic Messages
Message | Meaning | Action Required |
| No message on display. Power has | The control panel will be disabled until power returns. |
| been cut off to the spa. |
|
OHH | “Overheat” - The spa has shut down. | DO NOT ENTER THE WATER. Remove the spa cover |
| One of the sensors has detected 47.7˚C | and allow water to cool. Once the heater has cooled, |
| at the heater. | reset by pushing any button. If spa does not reset, shut |
|
| off the power to the spa and call your dealer or service |
|
| organization. |
OHS | “Overheat” - The spa has shut down. | DO NOT ENTER THE WATER. Remove the spa cover and |
| One of the sensors has detected that | allow water to cool.At 41.6˚C, the spa should automatically |
| the spa water is 43.3˚C. | reset. If spa does not reset, shut off the power to the spa |
|
| and call your dealer or service organization. |
ICE | “Ice” - Potential freeze condition | No action required. The pumps and the blower will |
| detected. | automatically activate regardless of spa status. |
Sna | Spa is shut down. The sensor that is | If the problem persists, contact your dealer or service |
| plugged into the Sensor “A” jack is not | organization. (May appear temporarily in an overheat |
| working. | situation and disappear when the heater cools.) |
Snb | Spa is shut down. The sensor that is | If the problem persists, contact your dealer or service |
| plugged into the Sensor “B” jack is not | organization. (May appear temporarily in an overheat |
| working. | situation and disappear when the heater cools.) |
Sns | Sensors are out of balance. If this is | If the problem persists, contact your dealer or service |
| Alternating with the temperature, it | organization. |
| may just be a temporary Condition. If |
|
| the display shows only this message |
|
| (periodically blinking), the spa is shut |
|
| down. |
|
HFL | A substantial difference between the | If the water level is okay, make sure the pumps have |
| temperature sensors was detected. This | been primed. If problem persists, contact your dealer or |
| could indicate a flow problem. | service organization. |
2009 Portable Spa Owner’s Manual | Page 17 |
LTR20091001, Rev. A