Calvin Klein CAP2560OL manual Trouble Shooting Guide, Problem Cause Correction

Models: CAP2560OL

1 28
Download 28 pages 8.88 Kb
Page 10
Image 10

TROUBLE SHOOTING GUIDE

NOTE: REMOVE POWER SOURCE AND DRAIN TANK PRESSURE PRIOR TO MAKING ANY REPAIRS OR ADJUSTMENTS.

Problem

Cause

Correction

Unit will not run

Tank pressure exceeds “cut in” pressure

Once pressure drops below “cut in” pressure, the unit will start.

 

Extension cord causing excessive amp draw

Check guidelines for proper cord gauge

 

 

(use of extension cords is not recommended).

 

Fuse or circuit tripped

Replace fuse or breaker

 

Unit not turned on or not plugged in

Check pressure switch and verify that it is in the Auto position.

 

 

Verify that unit is plugged in.

 

Air filter plug not removed

Remove air plug and install Air filter.

 

Cold weather conditions

Place compressor in warmer environment for at least 30 minutes

 

(typically temperatures below freezing)

then try restarting.

Air leaks at fittings

Fittings loose

Tighten fitting. Check with soapy water. DO NOT OVER TIGHTEN.

Air leak at pressure switch

Clogged check valve

Remove and clean check valve

Unit will not build pressure

Application requires excessive air demand

Reduce demand on compressor

 

Loose head

Tighten bolts on head

 

Blown gasket

Remove head and check for broken or deformed gasket. Replace

 

 

if needed.

Unit will not build pressure

Worn or broken valves

Remove head and replace valves.

Air leak at tank or air tank

Damaged air tank

 

 

 

DO NOT DRILL INTO, WELD OR

welds.

 

 

 

 

OTHERWISE MODIFY AIR TANK.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DAMAGED OR MODIFIED TANKS

 

 

 

 

 

CAN RUPTURE. REPLACE TANK

 

 

 

 

 

IMMEDIATELY.

-10-

Page 10
Image 10
Calvin Klein CAP2560OL manual Trouble Shooting Guide, Problem Cause Correction