5.2.2 CAI Address Settings
The CAI address selection procedure will not affect the operation of the VORTEX but whilst this procedure is active, the volume cannot be adjusted by using the pots.
Briefly press the
The current address will then be displayed by the On LEDs.
Flashing of On LED channel A indicates the tens of the address
Flashing of On LED channel B indicates the units of the address
These sequences are repeated for 30 seconds (timeout). Then the On LEDs return to their normal function.
To change CAI address,turn the appropriate volume potentiometer to the required
address (volume pot channel A => TENS, volume pot channel B => UNITS).
USER MANUAL
VORTEX 6, 4, 2.6 and 200V
To see the address you can use the scale markings of the potentiometers. You will find the digits 0,1,...,9 on the 10 scale spacings.
|
| 4 | 5 |
|
| 3 | 6 |
|
| 2 | 7 |
4 | 5 | 1 | 8 |
| 9 | ||
3 | 6 | 0 |
27
18
0 | 9 |
The current selected address will be immediately displayed but not automatically stored or activated! After each turn of pot you have another 30 seconds to Timeout.You can exit this procedure without saving the new address by briefly pressing the
To store and activate the new address you have to press the
Be sure to set the
Example of LED sequences for different address settings:
Address | On LED Channel A ⇒TENS | On LED Channel B ⇒UNITS | ||
|
|
|
|
|
01 (factory settings) | 0* | flash | 1* | flash then short pause |
|
|
|
|
|
25 | 2* | flashes then short pause | 5* | flashes then short pause |
|
|
|
|
|
NOTE: Ensure you return both pots to their original position after address selection is complete, otherwise the amplifier will change its volume level to the new pot positions!