Operating Instructions and Parts Manual

AL2810

Airless Paint Systems

 

General Safety

This system is capable of producing

 

 

 

 

 

 

 

 

 

PRESSURE RELIEF PROCEDURE

 

 

3000 psi. Use only Campbell

 

 

Information (Cont.)

 

 

Before servicing or resting unit,

 

 

Hausfeld replacement parts rated

 

 

4. Do not smoke or eat when spraying

 

 

relieve pressure from system by

 

 

at 3000 psi or higher.

 

 

 

paint, insecticides, or other

Never spray without tip guard.

 

following this procedure:

 

 

flammable substances.

1.

Engage gun trigger lock.

 

 

Ensure trigger lock is functioning

 

5. Always work in a clean

2.

Turn off engine.

 

 

properly.

 

 

environment. To avoid injury and

 

 

 

 

 

 

 

 

 

 

Always engage trigger lock when

3.

Disengage

 

 

 

 

 

 

 

 

 

 

damage to the workpiece, do not

 

 

 

 

 

 

 

gun trigger

 

 

 

 

 

 

not spraying.

 

 

 

 

 

 

 

aim the spray gun at any dust or

 

 

 

 

 

 

 

 

 

 

 

lock and

 

 

 

 

 

Do not remove spray tip while

 

 

 

 

 

 

 

debris.

 

 

 

 

 

 

 

 

 

trigger gun

 

 

 

 

 

 

 

 

 

 

 

 

 

cleaning pump.

 

 

 

 

 

 

6. When spraying and cleaning,

 

 

 

to relieve

 

 

 

 

Never leave equipment pressurized

 

 

 

 

 

 

 

always follow the instructions and

 

 

residual fluid

 

 

 

 

 

 

 

 

 

 

 

 

safety precautions provided by the

 

while unattended.

 

 

pressure. Hold metal part of gun

 

 

material manufacturer (Refer to

Do not clean spray tip while it is

 

 

in contact with grounded metal

 

 

MSDS).

 

attached to the spray gun. Remove

 

 

pail.

 

 

 

 

 

 

 

 

 

 

 

 

spray tip from gun to clean tip

4.

Re-engage gun trigger lock.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

guard.

5.

Turn Prime/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ensure tightness of high pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gasoline engine precautions:

 

 

Pressure Relief

 

 

 

 

connections.

 

 

Valve to open

 

 

 

Locate unit 25 feet away from

 

 

 

 

 

 

Do not use pliers to tighten or

 

 

(priming)

 

 

 

 

spray area in well-ventilated area.

 

 

 

 

 

 

 

loosen high pressure connections.

 

 

position to

 

 

 

NEVER operate in closed building

 

 

 

 

 

 

Motor is equipped with an automatic

 

 

relieve fluid

 

 

 

 

unless exhaust is piped outside.

 

 

 

 

 

 

 

 

pressure.

 

 

 

 

 

thermal overload. Motor will restart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEVER allow hose to lay against

 

 

 

 

 

 

OPEN POSITION

 

 

 

without warning, after cooling.

6.

Leave Prime/

 

 

 

engine mufflers or hot parts.

 

 

 

 

 

 

 

 

 

Never aim or

 

 

Pressure Relief

 

 

 

NEVER refill fuel tank while engine

 

 

 

 

 

 

 

 

 

 

 

 

 

spray at yourself

 

 

Valve OPEN until you are ready to

 

 

 

 

 

 

 

 

 

is hot or running.

or anyone else or serious injury could

 

 

spray again.

 

 

 

 

 

 

 

 

 

 

 

occur.

 

NOTE: If spray tip or hose is clogged,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

follow Step 1 to 5 above. Expect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Skin Injection Hazard:

 

 

 

 

 

 

 

 

 

 

paint splashing into the pail while

 

FIRE OR EXPLOSION HAZARD:

 

 

relieving pressure during Step 5. If

 

High pressure spray

 

 

 

 

 

 

 

 

Do not use solvents with flash

 

 

 

 

 

 

you suspect that pressure has not

 

 

can inject toxins

 

 

 

 

 

 

 

 

points less than 70°F (21°C) to clean

 

been relieved after following the

 

 

into blood stream.

 

 

 

 

 

 

 

 

 

this equipment (examples of

 

above procedure, engage gun trigger

 

 

If injection occurs,

 

 

 

 

 

 

 

 

 

acceptable cleaning solvents are

 

lock and take your unit to an

 

 

 

 

 

 

 

seek emergency medical treatment.

 

 

 

 

 

water, mineral spirits, lacquer

 

authorized Campbell Hausfeld

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

thinner, Xylene and high flash

 

Service Center.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

napha. A partial example list of

 

 

 

 

 

 

 

 

Use a face mask/respirator

 

 

 

 

 

 

 

 

 

 

 

 

unacceptable cleaning solvents are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and protective clothing

 

 

 

 

 

 

 

 

 

 

 

 

 

low flash napha, mek, acetone,

electrical arcs that will ignite a

 

when spraying. Always

 

 

 

 

 

 

alcohol and toluene).

flammable gas or vapor. Never store

 

spray in a well ventilated

 

 

 

 

 

 

area to prevent health and fire

 

 

 

 

 

 

 

 

 

flammable liquids or gases in the

 

hazards. Refer to Material Safety Data

 

 

 

 

 

 

 

 

 

vicinity of the unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not spray acids,

 

Sheets (MSDS) of spray material for

Do not spray flammable

 

 

 

 

 

 

 

 

 

details.

materials in vicinity of

 

 

 

 

 

 

 

 

corrosive materials,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

toxic chemicals, fertilizers or pesticides.

 

Never try to stop leaks with any

open flame or near

 

 

 

 

 

 

Using these materials could result in

 

 

part of your body.

ignition sources. Motors, electrical

 

 

death or serious injury.

 

 

equipment and controls can cause

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.chpower.com