Operating Instructions

 

 

 

 

NB003006

Operating Instructions

5.

Depress the Work

5. Always unload all fasteners before

(Continued)

 

Contact Element

 

removing tool from service.

 

Sequential Trip Safety

 

(WCE) against the

 

Unloading is the reverse of loading,

 

work surface without

 

except always disconnect the air

Mechanism

 

 

This tool is equipped with a sequential

 

pulling the trigger.

 

hose before unloading.

 

 

 

The nailer must not operate.

 

 

 

 

 

trip safety mechanism. When the

 

Adjusting the Nail Penetration

 

Do not use the tool if it operates

operator depresses the Work Contact

 

1. Regulate the air pressure to 60 psi at

 

without pulling the trigger. Personal

Element (WCE) against the work surface

 

 

 

the nailer.

 

 

 

 

injury may result.

 

 

 

 

and then pulls the trigger, a fastener

 

 

 

 

 

 

 

 

 

 

 

6.

Remove the nailer

2. Connect the air supply and test for

will be driven.

 

penetration by driving nails into a

 

 

 

from the work

 

Operating a sequential trip

 

 

sample piece of wood. If the nails do

 

surface. The Work

 

nailer

 

 

not achieve the desired penetration,

 

Contact Element

 

1.

Release trigger and

 

 

adjust the air pressure to a higher

 

(WCE) must return to

 

 

place nose of tool

 

its original down position. The nailer

 

setting until the desired penetration

 

against work surface.

 

must not operate. Do not use

 

is achieved. Do not exceed 100 psi at

 

 

 

the tool if it operates while lifted

 

the nailer or durability of the nailer

 

 

 

 

will be reduced.

 

 

2.

Depress the Work

 

from the work surface. Personal

 

 

 

 

 

 

 

 

 

 

injury may result.

 

 

 

 

 

 

Contact Element

 

 

 

 

 

 

 

 

 

 

100

 

 

100

 

(WCE) against the

7. Pull the trigger and

 

 

 

 

 

50

150

50

150

 

work surface and pull

 

depress the work

 

0

200

0

200

 

the trigger to drive a

 

contact element

 

 

 

 

 

 

 

 

 

fastener.

 

(WCE) against the

 

 

 

 

 

3.

Release the trigger

 

work surface. The

 

 

 

 

 

 

nailer MUST NOT operate.

 

 

 

 

 

 

and lift the tool from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the work surface

8.

Depress the Work

 

 

 

 

 

 

after each fastener is

 

Contact Element

User - Maintenance

 

 

 

driven.

 

(WCE) against the

Instructions

 

 

Checking the Work contact

 

work surface. Pull the

Clearing A Jam From The Tool

 

trigger. The nailer

element (WCE)

 

 

 

 

 

 

 

MUST operate.

1.

Disconnect the air

 

 

 

Check the operation

 

 

 

 

 

An improperly

 

supply from the

 

 

 

of the Work Contact

 

 

 

 

 

 

functioning tool

 

nailer.

 

 

 

Element (WCE) trip mechanism before

 

 

 

 

 

must not be used. Do not actuate the

 

 

 

 

 

each use. The WCE must move freely

2.

Remove all nails from

 

 

tool unless the tool is placed firmly

 

 

without binding through its entire

against the work piece.

 

the magazine (See

 

 

travel distance. The WCE spring must

 

 

 

 

 

 

Loading/ Unloading

 

 

return the WCE to its fully extended

Loading/Unloading The Nailer

 

 

 

 

The Nailer). Failure

 

 

position after being depressed. Do

1. Always disconnect the tool from the

 

 

 

not operate the nailer if the WCE trip

 

to do so will cause the nails to eject

mechanism is not operating properly.

 

air supply before loading fasteners.

 

from the front of the nailer when

Personal injury may occur.

2. Lift up on the latch.

 

the nose assembly is removed.

 

 

 

1.

Disconnect the air

 

Pull back on the

3. Pull red tab forward

 

 

 

supply from the

 

magazine cover.

 

on quick clear nose.

 

 

 

nailer.

3. Insert a stick of

 

Set aside nose door to

 

 

 

 

 

 

 

2. Remove all nails from

 

Campbell Hausfeld

 

expose and remove

 

 

 

the magazine (see

 

nails or equivalent

 

jammed fastener.

 

 

 

Loading/ Unloading).

 

(See Fastener Section)

4. Reinstall nose in reverse order in

3. Make sure the trigger

 

into the magazine. Make sure

 

 

step 3.

 

 

 

 

the pointed ends of the nails are

 

 

 

 

 

and work contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

resting on the bottom ledge of the

5.

Make sure the trigger

 

 

 

element (WCE) move

 

 

 

 

 

magazine when loading. Make sure

 

and Work Contact

 

 

 

freely up and down

 

 

 

 

 

 

the nails are not dirty or damaged.

 

Element (WCE) move

 

 

 

without sticking or

 

 

 

 

 

 

 

 

freely up and down

 

 

 

binding.

4.

Push the magazine

 

 

 

 

 

without sticking or

 

 

4.

Reconnect air supply

 

cover forward until

 

 

 

 

 

binding.

 

 

 

 

the latch catches.

 

 

 

 

 

to the nailer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

www.chpower.com