Operating Instructions | Gravity Feed Spray Gun |
User - Maintenance Instructions (Continued)
4.Check and replace any damaged
5.Unscrew packing nuts and replace the packing ONLY if a leak will not stop when the nut is tightened (See Figure 5).. Do not
6.
Technical Service
Please call our Tool Hotline at
Tool Repair
Only qualified personnel should repair the tool and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently..
Storage
1.When not using spray gun, turn the fluid adjustment knob counterclockwise to open which
will reduce spring tension on needle fluid tip..
2.Spray gun must be well cleaned and lightly lubricated..
Troubleshooting Chart
Stop using tool immediately if any of the following problems occur. Serious personal injury could occur. Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.
Symptom | Possible Cause(s) | Corrective Action |
|
|
|
Right or left heavy spray pattern
1. | Holes in left or right side of the air cap | 1. | Clean.. Use only |
| are plugged |
|
|
2. | Dirt on left or right side of fluid tip | 2. | Clean |
Top or |
| 1. Dried material at top or bottom of fluid | 1. | Clean | ||||||
bottom |
|
| tip |
|
| |||||
heavy spray | 2. | Loose air cap or dirty seat | 2. | Clean and tighten | ||||||
pattern | ||||||||||
3. | Air cap plugged | 3. | Clean.. Use only | |||||||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |
Split spray | 1. | Fan pattern open too far | 1. | Partially close the pattern adjustment | ||||||
pattern | 2. | Fluid turned in too far | 2. | Increase fluid | ||||||
|
|
|
|
| ||||||
|
|
|
|
| 3. | Atomization air too high | 3. | Reduce atomization air pressure | ||
|
|
|
|
|
|
|
|
| ||
Center |
| 1. Fan adjustment partially closed | 1. | Open fan pattern adjustment | ||||||
heavy spray | 2. | Material too thick | 2. | Thin to proper viscosity | ||||||
pattern | ||||||||||
3. | Atomization pressure too low | 3. | Increase atomization pressure | |||||||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |
Sputtering | 1. | Material level too low | 1. | Refill | ||||||
spray |
| 2. | Container tipped too far | 2. | Hold more upright | |||||
|
|
|
|
|
| |||||
|
|
|
|
| 3. | Loose fluid inlet connection | 3. | Tighten | ||
|
|
|
|
| ||||||
|
|
|
|
| 4. | Loose or damaged fluid tip/seat | 4. | Adjust or replace | ||
|
|
|
|
| 5. | Dry or loose fluid needle packing nut | 5. | Lubricate and or tighten | ||
|
|
|
|
| 6. | Air vent clogged | 6. | Clear vent hole | ||
|
|
|
|
|
|
|
|
| ||
Fluid leaking from packing |
| 1. Packing nut loose | 1. | Tighten, but do not restrict needle | ||||||
nut | 2. | Packing worn or dry | 2. | Replace or lubricate | ||||||
|
|
|
|
|
www.chpower.com | 6 |