60 psi Min.
100 psi Max.

Operating Instructions

SB303000

Operating Instructions (Continued)

RECOMMENDED HOOKUP

The illustration below shows the recommended hookup for the tool.

1. The air compressor

must be able to maintain a minimum of 60 psi when the

tool is being used. An inadequate air supply can cause a loss of power and inconsistent driving.

2. An oiler can be used to provide oil circulation through the tool. A filter can be used to remove liquid and solid

impurities which can rust or “gum up” internal parts of the tool.

3.Always use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source if a regulator fails, or 150 psi, whichever is greater. Use 1/4 inch air hose for runs up to 50 feet. Use 3/8 inch or greater air hoses for 50 foot run or longer.

150 psi or greater

4.Use a pressure regulator on the compressor, with an operating pressure of 0 - 125 psi. A pressure regulator is required to control the operating pressure of the tool between 60 and 100 psi.

OPERATIONAL MODE - SINGLE CYCLE

Always know the operational mode of

the tool before using. Failure to know the operational mode could result in death or serious personal injury.

This tool requires the trigger to be pulled each time a nail is driven. The nailer can be actuated by depressing the WCE against the work surface followed by pulling the trigger.

The trigger must be released to reset the tool before another nail can be driven.

WORK CONTACT ELEMENT (WCE)

Check the operation of the Work Contact

Element (WCE) trip mechanism before each use. The WCE must move freely without binding through its entire travel distance. The WCE spring must return the WCE to its fully extended position after being depressed. Do not operate the nailer if the WCE trip mechanism is not operating properly. Personal injury may occur.

1. Disconnect the air supply from the tool.

2. Remove all fasteners from the magazine (see Loading/ Unloading).

3. Make sure the trigger and work contact element (WCE) move freely up and down without sticking or

binding.

4.Reconnect air supply to the tool.

5.Depress the Work

Contact Element (WCE) against the

work surface without pulling the trigger.

The tool MUST NOT OPERATE. Do not use the tool if it operates without pulling the trigger. Personal injury may result.

6. Remove the tool from

the work surface. The Work Contact

Element (WCE) must return to its original

down position. The tool MUST NOT OPERATE. Do not use the tool if it operates while lifted from the work surface. Personal injury may result.

7. Pull the

trigger

and depress

the work contact

element (WCE) against the work surface. The tool MUST NOT OPERATE.

8.Depress the Work

Contact Element

(WCE) against

the work surface. Pull the trigger. The tool MUST OPERATE.

An improperly functioning tool

must not be used. Do not actuate the tool unless the tool is placed firmly against the work piece.

Minimum Recommended Hookup

Quick Plug

Quick

Quick Plug

Coupler

Quick

Coupler

Air Hose

5

www.chpower.com