Campbell Hausfeld NB006401 Recommended Hookup, Operational Mode, Single Cycle Mode, Must Operate

Models: NB006401

1 12
Download 12 pages 60.59 Kb
Page 4
Image 4
PARA CARGAR Y DESCARGAR LA CLAVADORA
1. Siempre conecte la herramienta a la fuente de suminsitro de aire antes de colocarle los clavos.
70 psi Min.
110 psi Max.

Operating Instructions

Model NB006401

Manual de Instrucciones

Modelo NB006401

Operating The Nailer

(Continued)

RECOMMENDED HOOKUP

The illustration below shows the recommended hookup for the nailer.

1. The air com- pressor must be able to main- tain a minimum

of 70 psi when

the nailer is being used. An inade- quate air supply can cause a loss of power and inconsistent

OPERATIONAL MODE

Always know the ! WARNING operational mode

of the nailer before using. Failure to know the operational mode could result in death or serious personal injury.

SINGLE CYCLE MODE

This mode requires the trig-

ger to be pulled each time a nail

is driven. The

nailer can be actuated by depressing

4. Reconnect air supply to the nailer.

5.Depress the Work Contact Element (WCE)

against the work surface

1

without pulling the trigger. The nailer MUST NOT OPERATE. Do not use the tool if it operates without pulling the trigger. Personal injury

Cómo usar la

Clavadora (Continuación)

6.Remueva la clavadora de la superficie de trabajo. El Elemento de Contacto de

Trabajo tiene que volver a su posi- ción original. La clavadora NO DEBE OPERAR. No use la her- ramienta si opera mientras está lev- antada de la superficie de trabajo.

impulso. Introduzca tiras de clavos en la parte superior del cargador (A).

3.Presione el seguro (c) para liberar el mecanismo de impulso

4.No cargue sin que esté asegurado, ni con el gatillo apretado.

5.Siempre descargue el sujetador antes de remover la herramienta de servicio. La descarga se hace siguiendo el proceso inverso de la carga; sin embargo, siempre se tiene que desconectar la manguera de aire antes de descar- garla.

hacia abajo sin atascarse o pegarse después de cada ajuste.

PARA AJUSTAR

LA DIRECCION

DEL TUBO DE

ESCAPE

RotateGire

La clavadora mod-

elo NB006401 está equipada con un deflector ajustable de la dirección del tubo de escape. Éste le permite al usuario cambiar la dirección del tubo de escape. Simplemente mueva el deflector hacia la dirección deseada.

driving.

2. An oiler can be used to provide oil circulation through the nailer. A filter can be used to remove liquid and solid impurities which can rust or “gum up” internal parts of the nailer.

3.Always use air supply hoses with a minimum working pressure rating equal to or greater than the pres- sure from the power source if a reg- ulator fails, or 150 psi, whichever is greater. Use 3/8” air hose for runs up to 50’. Use 1/2” air hoses for 50’ run or longer. For better perfor- mance, install a 3/8” quick plug (1/4” NPT threads) with an inside diameter of .315” (8mm) on the nailer and a 3/8” quick coupler on the air hose.

150 psi or greater

3/8” I.D.

4.Use a pressure regulator on the compressor, with an operating pres- sure of 0 - 125 psi. A pressure regu- lator is required to control the oper- ating pressure of the nailer between 70 and 110 psi.

the WCE against the work surface fol- lowed by pulling the trigger.

The trigger must be released to reset the tool before another nail can be dri- ven.

WORK CONTACT ELEMENT (WCE)

Check the opera- ! CAUTION tion of the Work

Contact Element (WCE) trip mechanism before each use. The WCE must move freely without binding through its entire travel distance. The WCE spring must return the WCE to its fully extend- ed position after being depressed. Do not operate the nailer if the WCE trip mechanism is not operating properly. Personal injury may occur.

1. Disconnect the air supply from the nailer.

2.Remove all nails from the

magazine (see Loading/ Unloading).

3.Make sure the trigger and

work contact

element (WCE) movement move freely up

and down without sticking or bind- ing.

may result.

6.Remove the nailer from the work surface. The Work Contact

Element (WCE) must return to its original down position. The nailer MUST NOT OPERATE. Do not use the tool if it operates while lifted from the work surface. Personal injury may result.

7.Pull the trig-

ger and

 

 

depress the

 

 

work contact

1

2

element

 

 

(WCE) against the work surface. The nailer MUST NOT OPERATE.

8.

Depress the

 

 

Work Contact

 

 

Element

 

 

(WCE) against

2

 

1

 

the work sur-

 

 

face. Pull the trigger. The nailer

 

MUST OPERATE.

 

An improperly

! WARNING functioning tool must not be used. Do not actuate the tool unless the tool is placed firmly against the work piece.

LOADING/UNLOADING THE NAILER

1.Always connect the tool to the air supply before loading fasteners.

7.

Apriete el

 

 

CÓMO AJUSTAR LA PENETRACIÓN

 

gatillo y pre-

 

 

DEL CLAVO

 

sione el

 

 

La NB006401 viene equipada con un

 

Elemento de

 

 

 

1

2

mecanismo clavador de profundidad

 

Contacto de

 

 

 

ajustable. Esto le permite al usuario

 

Trabajo contra la superficie de tra-

 

determinar a qué profundidad se va a

 

bajo. La clavadora NO DEBE hacerse

 

clavar en la superficie de trabajo.

 

funcionar.

 

 

 

 

 

1. Ajuste la presión de operación a aquél-

 

 

 

 

8.

Presione el

 

 

la que usará con regularidad para

 

Elemento de

 

 

clavar los clavos. No exceda la presión

 

Contacto de

 

 

de operación máxima de la clavadora

 

Trabajo contra

1

2

modelo NB006401 de 7,58 bar.

 

la superficie de

 

 

2. Para dirigir el calador de clavos, gire

 

trabajo. Apriete el gatillo. La

 

 

 

la rueda (C) hacia la izquierda hasta

 

clavadora DEBE OPERAR.

 

 

 

el punto deseado.

 

 

 

 

! ADVERTENCIA Una

herramienta que funciona de manera inadecuada no debe usarse. No active la herramienta a menos que esté colocada firmemente contra la pieza de trabajo.

(C)

2. Tire el mecanismo de impulso (B)

 

hacia atrás hasta que el seguro (C) se

3. Para clavar el clavo más profundo,

enganche en el mecanismo de

gire la rueda (C)

 

(A)

hacia la derecha

hasta el punto

 

 

deseado.

(C)

4. Asegúrese que el

gatillo y el

 

(B)Elemento de Contacto de Trabajo se mueven libremente hacia arriba y

QUE HACER CUANDO LA CLAVADO- RA TENGA UN CLAVO ATASCADO

1. Desconecte la clavadora de la fuente de sum- inistro de aire.

2.

Remueva todos

 

los clavos del

 

depósito (vea

 

Carga /

 

Descarga).

 

Si no se

 

! ADVERTENCIA retiran

todos los sujetadores éstos saldrán por el frente de la herramienta.

3.Destrabe el gan- cho presionando

el botóns en el lado del car- gador. El botóns destrabará el gancho de la boquilla.

4.Ahora se puede girar la puerta, dejando al descu- bierto el sujeta- dor que esté trabado.

5.Retire todos los sujetadores que estén tra- bados, uti-

lizando unas pinzas o un destornil- lador si fuera

necesario.

6 Vuelva a girar la puerta a su posi- ción de cerrado.

www.chpower.com

4

5-Sp

Page 4
Image 4
Campbell Hausfeld NB006401 Recommended Hookup, Operational Mode, Single Cycle Mode, Work Contact Element WCE, Must Operate