Operating Instructions

SB660000

Operating Instructions (Continued)

Adjusting the Fastener

Penetration

The tool is equipped with an adjustable depth of drive feature. This allows the user to determine how deep a fastener will be driven into the work surface.

1.Adjust operating pressure so nails are driven consistently. Do not exceed 120 psi.

2.To drive the

nail shallower, turn the

wheel (C) (C) to right to

the extent desired.

3. To sink a nail deeper, turn the wheel

(C) to left to the extent desired.

4.Make sure

trigger and WCE move freely up and down without binding or sticking after each adjustment.

Adjusting The Direction Of The Exhaust

The tool is equipped

 

with an adjustable

 

direction exhaust

 

deflector. This is

 

intended to allow

Rotate

the user to change

 

the direction of the exhaust. Simply twist the deflector to any direction desired.

User - Maintenance

Instructions

Clearing A Jam From The Tool

1. Disconnect the air supply from the nailer.

2. Remove

all nails from the magazine (see Loading/

Unloading). Failure to do so will cause the nails to eject from the front of the tool.

3. Undo latch by pulling out and down. The wire latch will disengage

from the hooks on the nose.

4. The door can now be rotated, exposing the jammed fastener.

5. Remove the jammed fastener, using pliers or a screwdriver if required.

6 Rotate door back into the closed position.

7. Extend the wire latch and place over the hooks on the nose.

8. Close the latch by pushing the latch up and in until the latch snaps into place.

9. Make sure the trigger and WCE move freely up and down without sticking or binding.

Technical Service

Please call our Tool Hotline at 1-800- 543-6400 with any questions regarding the operation or repair of this tool or for additional copies of this manual.

Fastener And Replacement Parts

Use only genuine Campbell Hausfeld

18 gauge fasteners (or equivalent - see Fastener Interchange Information). Tool performance, safety and durability could be reduced if improper fasteners are used. When ordering replacement parts or fasteners, specify by part number.

Tool Repair

Only qualified personnel should repair the tool and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently.

Assembly Procedure For Seals

When repairing a tool, the internal parts must be cleaned and lubricated. Parker O-lube or equivalent must be used on all o-rings. Each o-ring must be coated with O-lube before assembling. A small amount of oil must be used on all moving surfaces and pivots. After reassembling, a few drops of 30W non-detergent oil or equivalent, must be added through the air line before testing.

Storage

The tool should be stored in a cool dry place.

www.chpower.com