•Replace the black tip and screw it on finger tight.
Note: There is also an extra black tip included with the machine, just in case you lose the first one.
9. Automatic Monitoring Controls
The C1300 has automatic monitoring controls. The display will show when cleaning, refilling and any other maintenance is necessary. Here are the messages:
PLEASE WAIT / HEATING UP
The C1300 is heating up. Wait until a different message appears.
RINSE MACHINE / PRESS BUTTON
You must push the BUTTON. Hot water pumps through the coffee spouts and stops by itself. During this procedure the display shows RINSING.
HOT WATER CYCLE NECESSARY
Place a cup under the frother and turn the SW Dial to the hot water position (fig. 2c). When the cycle stops, turn the SW Dial back to the
SET STEAM/WATER / DIAL TO ZERO
The SW Dial is either in the steam or hot water position (fig. 2b or 2c). Turn the SW Dial to the
HEATING UP
The ThermoBlock is heating for steaming. Wait until the display reads STEAM READY / PRESS BUTTON (see chapter 8.3).
TRAY MISSING
The tray is missing or not inserted properly.
CLEAN UNIT
This message will alternate with the regular message. See chapter 12.1.
DECALCIFYING NECESSARY
Message will alternate with the regular message. See chapters 12.2 and 12.3.
EMPTY TRAY
The tray needs to be removed and the contents emptied. As long as this message appears all other functions are blocked. See chapter 9.1.
FILL / WATER TANK
There is not enough water in the water tank or the water tank is empty. As long as this message appears all other functions are blocked. CHANGE FILTER It is time to replace the Claris Filter Cartridge. See chapters 11 through 11.2.
9.1 Empty Tray
When the display reads EMPTY TRAY all other functions are blocked. Move the coffee spout up and carefully lift up the tray and pull it out (fig. 16). The tray has a total of four parts (fig. 1a).
•Remove the Used Coffee Container and empty it. This container holds between 10 and 16 coffee portions, depending how large the used coffee portions are.
•Discard the water in the tray. This water is the result of the ThermoBlock system: after each brew cycle it forces the remaining water into the tray. This way you never have any stale water inside the heating system. Clean all
parts and assemble.
Important: Make sure that the used coffee container is placed onto the supporting tray before inserting the complete tray back into the machine. Otherwise, used coffee will fall into the tray causing an overflow.
13