Carrier 38CKC(Q) instruction manual ÐSplit-SystemAir Conditioner, Safety Considerations

Models: 38CKC(Q)

1 8
Download 8 pages 26.09 Kb
Page 1
Image 1
38CKC(Q), 38CMC, 38BRC Split-System Air Conditioner

38CKC(Q), 38CMC, 38BRC Split-System Air Conditioner

Visit www.carrier.com

Installation and Start-Up Instructions

NOTE: Read the entire instruction manual before starting the installation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thor- oughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements.

Recognize safety information. This is the safety-alert symbol Installation and Start-Up Instructions . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.

Understand the signal words DANGER, WARNING, and CAU- TION. These words are used with the safety-alert symbol. DAN- GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.

Before installing, modifying, or servicing system, main elec- trical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label. Electrical shock can cause personal injury or death.

INSTALLATION RECOMMENDATIONS

NOTE: In some cases noise in the living area has been traced to gas pulsations from improper installation of equipment.

1. Locate unit away from windows.

A97005

Fig. 1ÐSplit-System Air Conditioner

7.Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap which comes in direct contact with the tubing. (See Fig. 2.)

8.Ensure that tubing insulation is pliable and completely sur- rounds vapor tube.

9.When necessary, use hanger straps which are 1 in. wide and conform to shape of tubing insulation. (See Fig. 2.)

10.Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation.

When outdoor unit is connected to factory-approved indoor unit, outdoor unit contains system refrigerant charge for operation with factory-approved indoor unit of the same size when connected by 15 ft of field-supplied tubing. For proper unit operation, check refrigerant charge using charging information located on control box cover.

INSTALLATION

2.Ensure that vapor and liquid tube diameters are appropriate to capacity of unit. (See Model Specific Instructions for proper tube sizing.)

3.Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends.

4.Leave some slack between structure and unit to absorb vibration.

Step 1ÐCheck Equipment and Jobsite

INSPECT EQUIPMENT Ð If shipment is damaged or incom- plete, file claim with shipping company prior to installation. Locate unit rating plate on unit service panel. It contains informa- tion needed to properly install unit. Check rating plate to be sure unit matches job specifications.

Step 2ÐInstall on a Solid, Level Mounting Pad

5.When passing refrigerant tubes through the wall, seal opening with RTV or other pliable silicon-based caulk. (See Fig. 2.)

6.Avoid direct tubing contact with water pipes, ductwork, floor joists, wall studs, floors, and walls.

If conditions or local codes require the unit be attached to pad, use tiedown bolts to fasten through knockouts provided in unit base pan. Refer to Fig. 3 for pad dimensions and dimensions needed to mount unit to pad.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

1

4

PC 101

Catalog No. 533-840

Printed in U.S.A.

Form 38BRC-1SI

Pg 1

2-97

Replaces: New

Tab

3a

2a

 

 

 

 

 

 

 

Page 1
Image 1
Carrier 38CKC(Q) instruction manual ÐSplit-SystemAir Conditioner, Installation and Start-UpInstructions