Carrier 48HJ004-014 To Shut Unit Off, Maintaining Your Unit, A - Gas Valve Location 48HJ004-007

Models: 48HJ004-014

1 8
Download 8 pages 58.71 Kb
Page 2
Image 2
Fig. 1A — Gas Valve Location

COMPRESSOR ACCESS PANEL

INTAKE LOUVERS

GAS VALVE

FLUE OPENING

Fig. 1A — Gas Valve Location

(48HJ004-007)

Fig. 1B — Gas Valve Location

(48HJ008-014)

TO SHUT UNIT OFF

1.Do not turn off the electrical power to unit without first turning off the gas supply.

2.Never attempt to manually light the main burners on unit with a match, lighter, or any other flame. If the electric sparking device fails to light the main burners, refer to the following shutdown procedures. Call your dealer as soon as possible.

Failure to follow these procedures can result in fire, seri- ous injury or death.

Refer to Fig. 3 while proceeding with the following steps.

Step 1 — Set room thermostat to lowest temperature setting and set SYSTEM switch to OFF.

Step 2 — Close the external manual gas valve.

Step 3 — Turn off the electrical power supply to unit; install lockout tag.

Step 4 — Remove the compressor access panel.

Step 5 — Move the gas valve switch to the OFF position. Step 6 — Replace compressor access panel.

Step 7 — If unit is being shut down because of a malfunc- tion, call your dealer as soon as possible.

If unit is being shut down because the heating season has ended, restore electrical power to the unit and set thermostat to the COOL position to ensure operation of the cooling system during the cooling season.

Should overheating occur, or the gas supply fail to shut off, shut off the manual gas valve to the unit before shutting off the electrical supply.

Do not use this unit if any part has been under water. Imme- diately call a qualified service technician to inspect the unit and to replace any part of the control system and gas control that has been under water.

MAINTAINING YOUR UNIT

All maintenance should be handled by skilled, experienced personnel. Your Carrier service technician can help you set up a maintenance schedule.

For your safety, keep the area around the unit clear and free of combustible materials, gasoline, and other flammable liq- uids and vapors.

To ensure proper functioning of the unit, flow of combus- tion and ventilating air must not be obstructed from reaching the unit. Clearance of at least 3 ft on flue and condenser sides and 6 in. on all other sides is required.