48HJ004-014 Single-Package Rooftop Heating/Cooling Units

User’s Information Manual

NOTE TO INSTALLER:

This manual should be left with the equipment owner.

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Improper installation, adjustment, alteration, ser- vice or maintenance can cause property damage, serious injury or death. Refer to this manual. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

Before performing recommended maintenance, be sure main power switch to unit is turned off. Electrical shock could cause serious injury or death.

Your rooftop combination heating/cooling unit is equipped with an automatic direct spark ignition and induced-draft com- bustion blower.

Do not attempt to light by hand; serious injury or death may result.

TO LIGHT UNIT

1.Do not turn off the electrical power to unit without first turning off the gas supply.

2.Before attempting to start the gas heating section, familiarize yourself with all the procedures that must be followed.

If you do not follow these instructions exactly, a fire or explosion may result. Property damage, injury, or loss of life could occur.

See Fig. 1A and 1B for location of gas valve. Refer to Fig. 2 while proceeding with the following steps.

Step 1 — Set room thermostat to the lowest temperature setting and set SYSTEM switch to HEAT or AUTO. position.

Step 2 — Close the manual gas valve.

Step 3 — Turn off the electrical supply to the unit, tag disconnect.

Step 4 — Remove the compressor access panel.

Step 5 — Move the gas valve switch to the OFF position and wait 5 minutes.

Step 6 — Move the gas valve switch to the ON position. Step 7 — Replace the compressor access panel.

Step 8 — Turn on the electrical supply to unit. Step 9 — Open the manual gas valve.

Step 10 — Set room thermostat selector slightly above room temperature to start unit. The induced-draft combustion air fan will start. Main gas valve will open and main burners should ignite within 5 seconds. If the burners do not light, there is a 22-second delay before another 5-second try. If the burner still does not light, the time delay is repeated. If the burner does not light within 15 minutes, there is a lockout. To reset the con- trol, break the 24-v power to W1. Repeat Steps 1-10. If burners still do not light, call for service.

Step 11 — Set the temperature selector on room thermostat to desired setting.

If the main burners fail to light, or the blower fails to come on, shut down gas heating section and call your dealer for service. Failure to follow these requirements could result in serious injury or death.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

1

4

PC 111

Catalog No. 534-80017

Printed in U.S.A.

Form 48HJ-2SO

Pg 1

11-00

Replaces: 48GJ,HJ-1SO

Tab

1a

6a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 1
Image 1
Carrier 48HJ004-014 specifications User’s Information Manual, To Light Unit

48HJ004-014 specifications

The Carrier 48HJ004-014 series is a sophisticated line of rooftop HVAC units that are engineered for energy efficiency and superior temperature control. As part of Carrier's extensive range of commercial heating, ventilation, and air conditioning systems, these units are designed to cater to various applications, making them ideal for office buildings, retail spaces, and other commercial establishments.

One of the standout features of the Carrier 48HJ004-014 is its impressive energy efficiency. These units are equipped with advanced scroll compressors that optimize energy consumption while delivering reliable cooling and heating performance. The series boasts high SEER (Seasonal Energy Efficiency Ratio) and EER (Energy Efficiency Ratio) ratings, ensuring that businesses can manage their operational costs effectively.

In addition to energy efficiency, the 48HJ004-014 series incorporates innovative technologies that enhance performance. The units are designed with a multi-speed blower system that allows for precise airflow control, ensuring that indoor spaces maintain consistent and comfortable temperatures. This capability not only improves occupant comfort but also contributes to better energy management.

The Carrier 48HJ004-014 units are built with durability in mind. The robust construction includes a galvanized steel cabinet with a powder-coated finish, providing excellent resistance to corrosion and environmental stressors. This ensures a long lifespan for the equipment and minimizes maintenance needs, allowing businesses to focus more on their core operations.

Moreover, the series is equipped with advanced controls that simplify operation and improve efficiency. The intelligent control systems enable remote monitoring and management capabilities, allowing facility managers to adjust settings based on real-time conditions. This functionality is crucial for optimizing energy use and maintaining indoor air quality.

The Carrier 48HJ004-014 also prioritizes environmental considerations with options for environmentally friendly refrigerants, aligning with sustainability goals. The commitment to reducing carbon footprint while delivering high-performance heating and cooling solutions demonstrates Carrier's dedication to promoting greener technologies.

In summary, the Carrier 48HJ004-014 series stands out for its energy efficiency, innovative technologies, robust construction, and advanced control systems. This makes it a preferred choice for businesses seeking reliable and efficient HVAC solutions that enhance indoor comfort while also contributing to sustainable practices.