ARI* CAPACITIES
Cooling Capacities and Efficiencies
|
|
|
|
|
| |
UNIT 50XP | NOMINAL TONS | STANDARD CFM | NET COOLING | EER** | SEER† | |
CAPACITIES (Btuh) | ||||||
|
|
|
|
| ||
024 | 2 | 770 | 24,000 | 11.0 | 13.2 | |
030 | 960 | 29,000 | 11.0 | 13.0 | ||
036 | 3 | 1100 | 36,000 | 11.2 | 13.5 | |
042 | 1450 | 41,000 | 11.2 | 13.0 | ||
048 | 4 | 1450 | 45,000 | 11.0 | 13.0 | |
060 | 5 | 1710 | 57,000 | 11.0 | 13.0 |
50XP
LEGEND
* Air Conditioning & Refrigeration Institute.
**At “A”
{Rated in accordance with U.S. Government DOE Department of Energy) test procedures and/or ARI Standards 210/240.
Notes:
1.Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on:
Cooling Standard: 80°F (26.7_C) db, 67°F wb (19.4_C) indoor
2.Before purchasing this appliance, read important energy cost and effi- ciency information available from your retailer.
A-Weighted Sound Power (dBA)
50XP | STANDARD |
| TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment) |
| |||||
RATING |
|
|
|
|
|
|
| ||
125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | |||
| (dBA) | ||||||||
|
|
|
|
|
|
|
|
| |
024 | 72 | 58.8 | 63.5 | 67.2 | 66.9 | 63.7 | 58.3 | 50.0 | |
|
|
|
|
|
|
|
|
| |
030 | 72 | 58.8 | 63.5 | 67.2 | 66.9 | 63.7 | 58.3 | 50.0 | |
|
|
|
|
|
|
|
|
| |
036 | 72 | 60.7 | 63.3 | 66.8 | 66.5 | 64.2 | 60.3 | 53.0 | |
|
|
|
|
|
|
|
|
| |
042 | 72 | 56.7 | 62.8 | 67.8 | 67.4 | 63.7 | 57.7 | 50.8 | |
|
|
|
|
|
|
|
|
| |
048 | 78 | 62.4 | 69.9 | 71.3 | 73.4 | 70.0 | 66.3 | 60.1 | |
|
|
|
|
|
|
|
|
| |
060 | 78 | 63.5 | 67.6 | 71.8 | 75.5 | 71.0 | 68.1 | 59.9 |
*Tested in accordance with ARI Standard 270 (not listed in ARI).
4