S

E

1112

3.Turn OFF electrical supply to the furnace. (See Fig. 12.)

4.Remove main furnace door. (See Fig. 13.)

13

5.The gas valve will have a control switch to turn off and on. Turn the control switch on the gas control to the OFF position and wait 5 minutes. (See Fig. 14 or 15.) Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” on furnace label. If you don’t smell

gas, go to next step.

OFF

ON

OR

For 58MTB and 58MVB

16

 

M

1

O

P

3

F

 

F

 

2

 

C

 

 

 

ON

 

For 58MCB and 58MXB

17

6.After waiting 5 minutes, turn the control switch on the gas control to the ON position. (See Fig. 16 or 17.)

OR

OFF

ON

A05100

18

OP

E

N

For 58MTB and 58MVB

14

 

M

1

O

P

3

F

C

2

F

ON

For 58MCB and 58MXB

1920

7.Replace main furnace door. (See Fig. 18.)

8.Turn ON the electrical supply to the furnace and wait 1 minute. (See Fig. 19.)

9.Open the external manual gas valve. (See Fig. 20.)

10.Set the room thermostat to a temperature slightly above the room temperature. This will automatically signal the furnace to start.

11.When the furnace receives the start signal, the inducer is

15started. When the pressure switch senses that there is suf- ficient combustion air, the hot surface igniter is energized.