After the hot surface igniter is heated for 17 seconds, the gas valve permits gas to flow to the main burners. After ignition and a time delay of about 60 sec, the furnace blower will start. Variable-capacity furnaces start at low speed until the control makes the necessary adjustments to operate the blower at either the low- or high-heat speed.

 

NOTE: If the burners fail to ignite after 4 attempts, the fur-

 

nace control system will lock out. If lockout occurs, main

 

burners fail to light, or blower does not come on, shut down

For 58MTA and 58MVP

the furnace and call your dealer for service.

1412. Set your thermostat to the temperature that satisfies your comfort requirements.

OFF

ON

 

or

For 58MCA and 58MXA

15

6.After waiting 5 minutes, turn the control switch on the gas control to the ON position. (See Fig. 14 or 15.)

16

OP

E

SUGGESTION: Setting the thermostat back a few degrees—and compensating for the difference with warmer clothing—can make a big difference in your fuel consumption. The few degrees at the top of your thermo- stat “comfort level’’ are the most costly degrees to obtain.

When the room temperature drops below the temperature selected on the thermostat, the furnace will switch on auto- matically. When the room temperature reaches the tempera- ture selected on the thermostat, the furnace will be switched off automatically.

Some thermostats have a FAN mode with 2 selections: AUTO and ON. When set on AUTO, the furnace blower cycles on and off. In the ON mode, the furnace blower runs continu- ously. Continuous fan keeps the temperature level in your home more evenly balanced. It also permits the indoor air to be continuously filtered. ComfortFan™ –On all but the 58MCA, the blower speed can be increased or decreased if desired due to change of seasons, large gatherings in your home, etc. Simply change your FAN from ON to OFF for 1 to 3 seconds (or AUTO depending on your thermostat), and then return to ON. The blower will switch to the next higher speed. There are at least 3 speeds to choose from. If the blower is running on its highest speed, a request to change will direct the blower to return to its lowest speed.

SHUTTING DOWN YOUR FURNACE

Should you ever need to shut down your furnace for service or maintenance, you will need to turn the furnace off. The following procedures must be followed:

1.Set your room thermostat to the lowest temperature setting. (See Fig. 19.)

N

17

18

7.Replace main furnace door. (See Fig. 16.)

8.Turn ON the electrical supply to the furnace and wait 1 minute. (See Fig. 17.)

9.Open the external manual gas valve. (See Fig. 18.)

10.Set the room thermostat to a temperature slightly above the room temperature. This will automatically signal the furnace to start.

11.When the furnace receives the start signal, the inducer is started. When the pressure switch senses that there is suf- ficient combustion air, the hot surface igniter is energized.

®

19

2.Close the external manual gas valve (See Fig. 9.)

3.Turn off electrical supply to the furnace. (See Fig. 20.)

4.Remove main furnace door. (See Fig. 11.)

5.Turn the switch on the gas control to the OFF position. (See Fig. 21 or 22.)

6

Page 6
Image 6
Carrier 58MXA, 58MVP, 58MTA, 58MCA manual Shutting Down Your Furnace

58MXA, 58MCA, 58MVP, 58MTA specifications

The Carrier 58MXA is an advanced heating and cooling system that exemplifies Carrier's commitment to innovation, efficiency, and comfort. Designed with the modern homeowner in mind, this gas furnace boasts a range of features that make it stand out in today's market.

One of the primary characteristics of the 58MXA is its impressive efficiency ratings. With AFUE (Annual Fuel Utilization Efficiency) ratings reaching up to 80%, the furnace ensures that homeowners can enjoy warmth during the colder months without excessive energy consumption. This efficiency not only translates to lower utility bills but also contributes to a reduced carbon footprint, making it an eco-friendly choice for environmentally conscious consumers.

The 58MXA utilizes a two-stage heating system which allows for more precise temperature control. This feature enables the furnace to operate at a lower stage for most of the heating cycle, providing comfortable warmth while conserving energy. When temperatures plummet, the system seamlessly switches to a higher stage for added heating capacity, ensuring that homes remain cozy even in extreme cold.

Furthermore, the Carrier 58MXA is engineered with advanced airflow and quiet operation in mind. Its variable-speed blower motor allows for optimal airflow throughout the home, enhancing overall comfort by distributing heat evenly in each room. This system also operates at a significantly reduced sound level compared to standard furnaces, promoting a peaceful indoor environment.

The 58MXA comes equipped with an innovative smart thermostat option, allowing users to monitor and control their home's heating remotely. This capability provides convenience and the opportunity for additional energy savings, as homeowners can adjust settings on the go or set schedules to meet their specific needs.

Durability is another hallmark of the Carrier 58MXA. Constructed with high-quality materials and backed by a manufacturer’s warranty, this furnace is built to withstand the rigors of temperature fluctuations and heavy use. Regular maintenance is also simplified, allowing homeowners to ensure optimal performance over the years.

Overall, the Carrier 58MXA is a top-of-the-line heating solution that combines efficiency, comfort, and advanced technology. Its innovative features and robust design make it an excellent choice for homeowners seeking a reliable and effective heating system. Whether for new construction or upgrading an existing home, the 58MXA is poised to provide years of dependable service.