Carrier CPLPCONV006A00 LPGas Orifice Sizes, Gas Supply, Lp Gas Orifice, Lp Nominal, Manifold

Models: CPLPCONV006A00

1 8
Download 8 pages 56.33 Kb
Page 3
Image 3

 

 

Table 2–LP Gas Orifice Sizes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS SUPPLY

 

 

LP GAS ORIFICE

 

 

LP NOMINAL

 

 

MANIFOLD

 

 

PART NO.

 

 

NUMBER OF

 

PRESSURE

 

 

 

UNIT SIZES

HEATING

 

PRESSURE

 

 

AND SIZE

 

ORIFICES

 

(IN W/C) (LP)

 

 

 

 

INPUT (BTUH)

 

(IN W/G) (LP)

 

ALTITUDE (FT)

 

 

 

 

 

 

 

 

 

 

 

 

 

MIN

 

MAX

 

0–2000

 

2001–6000

018040

 

 

 

 

THIS KIT APPLIES TO MODELS WITH HEATING INPUT OF

024040

40,000

 

 

 

57,000 BTUH AND HIGHER. FOR 40,000 BTUH MODELS USE KIT # CPLPCONV008A00

030040

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024060

 

 

 

 

 

 

 

 

 

 

030060

57,000

2

 

4.0

 

13.0

3.5

LH32RF080

 

 

036060

 

 

No. 46

 

 

 

 

 

 

 

 

 

 

 

 

042060

 

 

 

 

 

 

 

 

 

THIS KIT APPLIES

036090

 

 

 

 

 

 

 

 

 

TO STANDARD ALTITUDE

 

 

 

 

 

 

 

 

 

INSTALLATIONS ONLY.

042090

85,500

3

 

4.0

 

13.0

3.5

LH32RF080

 

 

 

 

ABOVE 2000 FT

048090

 

 

No. 46

 

 

 

 

 

 

 

 

 

USE HIGH ALTITUDE

 

060090

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LP CONVERSION KIT

048115

 

 

 

 

 

 

 

LH32RF094

 

115,000

3

 

4.0

 

13.0

3.5

 

#CPLPCONV007A00

 

060115

 

 

No. 42

 

 

 

 

 

 

 

 

 

 

048130

127,000

3

 

4.0

 

13.0

3.5

LH32RF096

 

 

060130

 

 

No. 41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Page 3
Image 3
Carrier CPLPCONV006A00 LPGas Orifice Sizes, Gas Supply, Lp Gas Orifice, Lp Nominal, Manifold, Number Of, Pressure, Heating