18 Model PH61Important: Tothe Operator
Operating Screen Descriptions
When the machine is powered the system will
initialize. The screen will display “INITIALIZ ING”.
There will be four types of data the system will
check: LANGUAGE, SYSTEM DATA, CONFIG
DATA, and LOCKOUT DATA. During the
INITIALIZING... LANGUAGEscreen, the alarm will
be on. If the system data, configurationdata, or
lockout history data has become corrupt, the
following screen will alert the operator that the
system settings may have been changed.
NVRAM FAULT
RESET TO DEFAULTS
PRESS SEL KEY
Once the system has initialized the SAFETY
TIMEOUT screen is displayed and the alarm is
turned on.
SAFETY TIMEOUT
ANY KEY ABORTS
This screen will be displayed, with the alarm on, for
60 seconds or until any key is pressed.
After the safety timeout has been complet ed, and
the power switch is OFF, one of the following
screens is displayed.
The first screen is displayed if the machine is not in
a brush clean state. If any of the requirement s for a
brush clean have not been met, the time displayed
will remain at 5:00 minutes. When all the
requirements for a brush cleaning are met, and the
five minutes expire, the screen will change to the
second screen, which is the standard power switch
OFF screen.
POWER SWITCH OFF
TIME:4:40
HOPPER: 62.1
BARREL: 67.7
POWER SWITCH OFF
-=-=-=-=-=-
UNIT CLEANED
When the power switch is set in the ON position, the
system mode of operation screen is displayed. In
this example, the machine is ON, but no mode of
operation has been selected. The second line of the
display indicates whether there is a sufficient supply
of mix in the hopper or if there is a LOW or OUT m ix
condition. The third line of the display shows the
temperature of the mix hopper. After pres sing the
AUTO key, the last line of the display shows the
month anddate (MM = month, DD = day) thatthe
machine needs to be disassembled and brush
cleaned.
MODE: OFF
HOPPER TEMP: 35.5F
UNIT CLEANED
The next display indicates the freezer is operating in
two different modes. The following information is
given:
The machine is operating in the WASH and PUMP
modes, the temperature of the mix hopper is 40_F
(4.4_C), and the machine needs to be brush cleaned
on October 31st.
MODE: WSH-PMP
HOPPER TEMP: 40.0 F
BRUSH CLEAN ON: 10/31
The following displayspertain to the HEAT cycle:
While in the heating phase, you will see this display.
It shows the present temperature of the hopper .
MODE: HEAT
PHASE: HEAT
HOPPER TEMP: 140.0 F
BRUSH CLEAN ON: MM/DD