need not be perfect because there will be positive pressure inside the cover. Do not mount the dampers with their actuators hanging directly beneath the ductwork. It is best to mount the actuator facing in either the three or nine o’clock position.

For specific duct types, follow instructions below:

ROUND METAL DUCT WORK

1.Crimp end of branch duct.

2.Slip end of zone damper over end of duct work. Use self-tapping sheet metal screw to secure. (See Fig. 2.)

3.Properly seal joint using duct tape, mastic, or other approved method. Do not allow mastic to come in contact with actuator.

4.Insulate damper using 1-1/2 in. to 2-in. insulation. (Check your local codes.)

NOTE: All zone dampers and duct work must be properly supported according to local codes or SMACNA standards.

RECTANGULAR METAL DUCT WORK

1.

Make connections using S-lock and drives. (See Fig. 2.)

2.

Properly seal joint using duct tape, mastic, or other approved

1 1/2 " TO 2"

INSULATION

A95131

Fig. 3—Insulated Rectangular Metal Duct Work

ROUND FLEXIBLE DUCT WORK

1.Slip 1 end of flexible duct work over 1 end of zone damper. (See Fig. 4.)

method. Do not allow mastic to come in contact with actuator.

MOUNTING

HUB

ACTUATOR

HOUSING

FLEXIBLE

ZONE

DUCT

DAMPER

Fig 4—Round Flexible Duct Work

A95132

QUICK BLADE

OPN COM CLS

RELEASE

 

BUTTON (RED)

MOUNTING

 

PLATE

2.Secure flexible duct to zone damper using SMACNA or other approved method.

3.Properly seal joint using duct tape, mastic, or other approved method. Do not allow mastic to come in contact with actuator.

4.Insulate damper using 1-1/2 in. to 2-in. insulation. (Check your local codes.) (See Fig. 5.)

FIELD

INSTALLED

POWER WIRING

Fig. 1—Damper 24-vac Connections

S-LOCK

SUPPLY

AIR DUCT

C02083

NOTE: All zone dampers and duct work must be properly supported according to local codes or SMACNA standards.

1/2 STEEL STRAP

A95133

Fig. 5—Insulated Round Duct Work

RECTANGULAR FIBROUS GLASS DUCT WORK

DRIVE ZONE

DAMPER

Fig. 2—Rectangular Metal Duct Work A92478

3.Insulate damper using 1-1/2 in. to 2-in. insulation. (Check your local codes.) (See Fig. 3.)

1.Insert 1 end of zone damper into 1 end of fibrous glass duct work approximately 2 to 3 in. (See Fig. 6.)

2.Screw field-supplied screws and tabs into zone damper.

3.Properly seal joint using duct tape, mastic, or other approved method. Do not allow mastic to come in contact with actuator.

4.Insulate damper using 1-1/2 in. to 2-in. insulation. (Check your local codes.) (See Fig. 7.)

3

Page 3
Image 3
Carrier ZONECC3Z instruction manual Round Flexible Duct Work, A95131, A95132, C02083, A95133

ZONECC3Z specifications

The Carrier ZONECC3Z is a cutting-edge climate control solution that has made a significant impact in the HVAC (heating, ventilation, and air conditioning) industry. As a versatile and efficient system, the ZONECC3Z is particularly designed to address the specific needs of residential and commercial spaces, providing unparalleled comfort while optimizing energy usage.

One of the main features of the ZONECC3Z is its advanced zoning capabilities. This system allows users to create separate temperature zones within a building, ensuring that each area can be heated or cooled according to its unique requirements. This not only enhances comfort but also improves energy efficiency, as only the zones that require climate control are actively managed. With this system, occupants can enjoy personalized comfort in different rooms or areas, reducing energy waste and costs.

Incorporating state-of-the-art technology, the ZONECC3Z is equipped with smart controls that enable intuitive management of the system. Users can monitor and adjust settings remotely through a user-friendly mobile app or a web-based interface. This connectivity feature allows for seamless integration with smart home devices and automation systems, enhancing user convenience and enabling proactive energy management.

Another key characteristic of the ZONECC3Z is its variable-speed compressor technology. This feature allows the system to adjust its cooling and heating output dynamically, responding to real-time temperature changes. This results in a quieter operation and greater efficiency, as the system avoids the on-and-off cycling common in traditional HVAC units. Consequently, users benefit from consistent indoor temperatures and lower utility bills.

The ZONECC3Z is also designed with sustainability in mind. It employs eco-friendly refrigerants that significantly reduce greenhouse gas emissions. With energy efficiency ratings that often exceed industry standards, this system can play a vital role in reducing the carbon footprint of buildings, making it an attractive option for environmentally conscious consumers.

In summary, the Carrier ZONECC3Z stands out as a powerful, efficient, and flexible solution for modern climate control needs. Its zoning capabilities, smart technology integration, variable-speed operation, and commitment to sustainability make it an ideal choice for both residential and commercial applications. Whether it’s for a home seeking comfort or a business aiming for cost-effective energy management, the ZONECC3Z delivers exceptional performance and peace of mind.