Casablanca Fan Company 59022, 59018, 59019 Wiring, Ling, Note To connect the wires, hold

Models: 59019 59022 59018

1 16
Download 16 pages 7.74 Kb
Page 6
Image 6
Wiring

Wiring

Note: To connect the wires, hold

www.CasablancaFanCo.com

1.888.227.2178

 

 

the bare metal leads together and place a wire connector over them, then twist clockwise until tight.

 

 

M

 

O

R

 

F

 

 

CEI

LING

 

 

M

 

O

R

 

F

 

 

CEI

LING

Using an orange wire connector from theNote: To connect the wires, holdhardware bag:

Connect the 3 grounding wires (green, green/yellow stripe, or bare copper) coming from the ceiling, downrod, and ceiling bracket.

green/yellow stripe (grounding)

green

green

 

 

M

 

O

R

 

F

 

 

FAN

Using an orange wire connector:

Connect the black (ungrounded) wire from the ceiling to the black wire from the fan/receiver.

Connect the white (grounded) wire from the ceiling to the white wire from the fan/receiver.

black (ungrounded)

white (grounded)

black

white

R

 

 

 

 

 

E

 

 

 

 

T

F

 

 

 

A

 

O

 

 

 

 

 

L

 

 

 

M

 

P

 

 

 

 

G

 

 

 

 

 

CEILIN

 

 

 

 

Refer to CAUTION c.1 on pg. 2

F

A

 

RO MF

N

 

 

Turn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box.