2273-9

Calibrating the Temperature Sensor

The temperature sensor of this watch is calibrated at the factory before shipment and further adjustment is normally not required. If you notice serious errors in the temperature readings produced by the watch, you can calibrate the sensor to correct the errors.

Important!

Incorrectly calibrating the temperature sensor can result in incorrect readings. Carefully read the following before doing anything.

Compare the readings produced by the watch with those of another reliable and accurate thermometer.

If adjustment is required, remove the watch from your wrist and wait for 20 or 30 minutes to give the temperature of the watch time to stabilize.

To calibrate the temperature

1.Enter the Barometer/Thermometer Mode.

2.Hold down A until the message OFF

appears (flashing), which indicates the setting screen.

A temperature value appears instead of OFF (factory calibration) if you previously calibrated the temperature sensor.

3.Each press of E increases the displayed temperature by 0.1°C (or 0.2°F) while pressing B decreases it.

Pressing B and E at the same time returns to the factory calibration (OFF).

4.Press A to return to the Barometer/Thermometer Mode screen.

Calibrating the Barometric Pressure Sensor

The pressure sensor of this watch is calibrated at the factory before shipment and further adjustment is normally not required. If you notice serious errors in the barometric pressure readings produced by the watch, you can calibrate the sensor to correct the errors.

Important!

Incorrectly calibrating the barometric pressure sensor can result in incorrect readings. Before performing the calibration procedure, compare the readings produced by the watch with those of another reliable and accurate barometer.

To calibrate the barometric pressure

1. Enter the Barometer/Thermometer Mode.

2. Hold down A until the message OFF appears (flashing), which indicates the setting screen.

A temperature value appears instead of OFF (factory calibration) if you previously calibrated the temperature sensor.

3.Press D to move the flashing to the barometric pressure calibration setting.

At this time, OFF or the barometric pressure value should be flashing on the display.

4.Each press of E increases the displayed barometric pressure by 1 hPa/ mb (0.05inHg), while pressing B decreases it.

Pressing B and E at the same time returns to the factory calibration (OFF).

5.Press A to return to the Barometer/Thermometer Mode screen.

CITY DATA LIST

Location

GMT Differential

Longitude

Lunitidal Interval

ANCHORAGE

–9.0

150°W

5:40

BAHAMAS

–5.0

77°W

7:30

BAJA, CALIFORNIA

–7.0

110°W

8:40

BANGKOK

+7.0

100°E

4:40

BOSTON

–5.0

71°W

11:20

BUENOS AIRES

–3.0

58°W

6:00

CASABLANCA

+0.0

8°W

1:30

CHRISTMAS ISLAND

+14.0

157°W

4:00

DAKAR

+0.0

17°W

7:40

GREAT BARRIER REEF, CAIRNS

+10.0

146°E

9:40

GUAM

+10.0

145°E

7:40

HAMBURG

+1.0

10°E

4:50

HONG KONG

+8.0

114°E

9:10

HONOLULU

–10.0

158°W

3:40

JAKARTA

+7.0

107°E

0:00

JEDDAH

+3.0

39°E

6:30

KARACHI

+5.0

67°E

10:10

KONA, HAWAII

–10.0

156°W

4:00

LIMA

–5.0

77°W

5:20

LISBON

+0.0

9°W

2:00

LONDON

+0.0

0°E

1:10

LOS ANGELES

–8.0

118°W

9:20

MALDIVES

+5.0

74°E

0:10

MANILA

+8.0

121°E

10:30

MAURITIUS

+4.0

57°E

0:50

MELBOURNE

+10.0

145°E

2:10

MIAMI

–5.0

80°W

7:30

NOUMEA

+11.0

166°E

8:30

PAGO PAGO

–11.0

171°W

6:40

PALAU

+9.0

134°E

7:30

PANAMA CITY

–5.0

80°W

3:00

PAPEETE

–10.0

150°W

0:10

RIO DE JANEIRO

–3.0

43°W

3:10

SEATTLE

–8.0

122°W

4:20

SHANGHAI

+8.0

121°E

1:20

SINGAPORE

+8.0

104°E

10:20

SYDNEY

+10.0

151°E

8:40

TOKYO

+9.0

140°E

5:18

VANCOUVER

–8.0

123°W

5:10

WELLINGTON

+12.0

175°E

4:50

Based on data as of January 2000.