Operation Guide 3184

Receive failed

If there was a previously successful reception on the current day

If no reception was successful

If the latest reception fails but a previous reception was successful on the current day, the settings updated indicator will be on the display.

Note

To interrupt a receive operation and return to normal timekeeping, press D.

Measuring Units and Ranges

Dive Time

Unit: 1 second

Range: 23:59'59'' (24 hours)

Dive Interval Time

Unit: 1 minute

Range: 47:59' (48 hours)

When the interval time exceeds the above range, interval time measurement automatically stops and the current interval time disappears from the screen of the newest diving log record.

About the Interval

The interval is time that elapses between the stop of the last dive and the start of the next dive. The watch starts an interval measurement whenever you press A at the end of a dive to reset dive time measurement.

Note that the current ongoing interval time is shown on the screen of the newest

record in diving log memory. It is not displayed in the Diving Mode. For information

about viewing diving log records, “Diving Log Records”.

The interval is displayed on the screen of the newest diving log, only while an

To turn auto receive on and off

1. In the Timekeeping Mode, press D to display the last successful receive time and date screen.

 

 

2. Hold down A until the current auto receive setting (

 

 

 

or

) starts to flash. This is the setting screen.

 

 

 

Note that the setting screen will not appear if the

 

 

 

currently selected Home City is one that does not

 

 

 

support time calibration reception.

 

 

 

3. Press D to toggle auto receive on ( ) and off (

).

On/Off status

4. Press A to exit the setting screen.

 

 

 

For information about city codes that support signal

 

receive, see “To specify your Home City”.

To check the latest signal reception results

In the Timekeeping Mode, press D to view the last successful receive time and date. Press D again to return to the previous screen.

The watch also will return to normal timekeeping if you do not perform any button operation for about one or two minutes.

Signal Reception Troubleshooting

Check the following points whenever you experience problems with signal reception.

Problem

Probable Cause

What you should do

Cannot perform

The watch is not in the

Enter the Timekeeping Mode

manual receive.

Timekeeping Mode.

and try again.

 

Your current Home City is not

Select LIS, LON, MAD, PAR,

 

one of the following: LIS, LON,

ROM, BER, STO, ATH, MOW,

 

MAD, PAR, ROM, BER, STO,

HKG, BJS,TPE, SEL, TYO,

 

ATH, MOW, HKG, BJS,TPE,

HNL, ANC,YVR, LAX, YEA,

 

SEL, TYO, HNL, ANC,YVR,

DEN, MEX, CHI, NYC, YHZ,

 

LAX, YEA, DEN, MEX, CHI,

or YYT as your Home City.

 

NYC, YHZ, or YYT

 

Auto receive is

You changed the time setting

Perform manual signal receive

turned on, but

manually.

or wait until the next auto

the settings

The DST setting was changed

signal receive operation is

updated

manually in the World Time

performed.

indicator does

Mode.

Check to make sure the watch

not appear on

You pressed a button while

is in a location where it can

the display.

signal receive was in progress.

receive the signal.

 

Even if receive is successful,

 

 

the settings updated indicator

 

 

will disappear from the display

 

 

each day when the first auto

 

 

receive operation of the day is

 

 

performed.

 

 

Time data (hour, minutes,

 

 

seconds) only was received

 

 

during the last receive

 

 

operation. The settings updated

 

 

indicator appears only when

 

 

time data and date data (year,

 

 

month, day) are both received.

 

Time setting

If the time is one hour off, the

Change the DST setting to

is incorrect

DST setting may be incorrect.

Auto DST.

following

The Home City code setting is

Select the correct Home City

signal

not correct for the area where

code.

reception.

you are using the watch.

 

For further information, see “Important!” under “Time Calibration Signal Reception” and “Radio-controlled Atomic Timekeeping Precautions.

Using the Diving Mode

You can use the Diving Mode to keep log records of the duration of each of your dives. Each log record includes a log number, the dive time, and the dive start date and time. There is enough memory to hold up to 10 diving log records. You can use the Diving Log Recall Mode to display diving log records currently in memory.

Use C to enter the Diving Mode as shown under “General Guide”.

If you leave the watch in the Diving Mode for about 11 to 12 hours, it will automatically switch to the Timekeeping Mode.

Diving Mode Screens

Dive Time Measurement

Ongoing Dive Time

 

 

Reset Screen

Measurement Screen

Mode name

Dive start time

 

 

 

 

 

 

 

 

 

 

 

Dive Graph

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dive time (hours,

Current time

Dive time (hours,

Current time

minutes, seconds)

 

minutes, seconds)

 

Graphic Area

The Dive Graph indicates the current dive time in minutes. While a dive time measurement operation is in progress, the current minute of the dive flashes in the graph.

The Dive Graph time does not include interval time.

interval timing operation is in progress.

Starting and Stopping Dive Time Measurement

Be sure to recharge the battery by exposing the watch

to light before starting a dive.

To start dive time measurement

In the Diving Mode, press D.

To stop dive time measurement

While a dive time measurement operation is in progress, hold down D for about one second.

Pressing D again without resetting the dive time measurement (see below) will cause timing to resume from where it was stopped.

To reset a dive time measurement and start interval measurement

While dive time measurement is stopped, press A.

This creates new diving log record with the currently displayed dive time information and starts interval measurement. Current ongoing interval measurement is shown on the screen of the newly created record.

To reset a dive time measurement and exit the Diving Mode

While dive time measurement is stopped, hold down C for about one second.

This creates new diving log record with the currently displayed information and exits the Diving Mode to the Timekeeping Mode.

See “Diving Log Records” for more information.

Diving Time Measurement Example

Single dive

DStart DStop

Dive time

0:00'00'' 0:20'13''

 

 

Dive interval time

0:00'00''

Interval measurement is

AReset

possible up to 47:59'59''

Multiple dives and intervals

DStart

DStop

DStart

DStop

 

 

Dive Time 1

 

 

Dive Time 2

 

 

 

 

 

 

 

 

 

 

 

 

0:00'00''

0:15'10''

0:00'00''

0:17'15''

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval 1

 

 

 

Interval 2

 

 

 

0:00'00''

0:20'16''

0:00'00''

 

 

 

 

AReset

 

 

A Reset

Important!

Pressing D again after stopping dive time measurement will cause timing to resume from where it was stopped.

Dive time/interval measurement continues internally if you exit the Diving Mode without resetting. A diving log record is not created in this case.

Diving Log Records

A new diving log record is created whenever you reset a dive time measurement, either by pressing A to start interval measurement or by holding down C to exit the Diving Mode.

Each diving log record includes a log number, the dive time, the dive start date and time, and the interval prior to the dive (if there was one).

There is enough memory for 10 diving log records. If there are already 10 diving log records in memory when you perform a reset operation, the oldest record currently in memory is deleted automatically to make room for the new record.

To view diving log records

1.In the Timekeeping Mode, press C to enter the Diving Log Recall Mode.

This displays the newest record in memory.

The interval currently being measured is displayed on the screen of the newest diving log record.

-:-- will appear on the screen if there is no diving log data stored in memory.

If you do not perform any operation for about one or two hours in the Diving Log Recall Mode, the watch will automatically return to the Timekeeping Mode.

2.Press D to scroll through the log records, from newer to older.

Log numbers are lower for older log records.

Newest Record

 

 

Log record

 

Log record

 

 

number

 

number

 

 

 

D

 

 

 

 

 

Dive start

Dive time

Dive interval

Dive start

Dive time Dive start date

time

 

time

time

(month, day)

3

Page 3
Image 3
Casio 3184 manual Using the Diving Mode