Operation Guide 5242

Specifications

Accuracy at normal temperature: ± 15 seconds a month (with no signal calibration)

Timekeeping: Hour, minutes (hand moves every 10 seconds), seconds, day, day of the week Calendar system: Full Auto-calendar pre-programmed from the year 2000 to 2099

Other: Home City code (can be assigned one of 29 city codes and Coordinated Universal Time); Daylight Saving Time (summer time) / Standard Time

Time Calibration Signal Reception: Auto receive up to six times a day (5 times a day for the Chinese calibration signal; Remaining auto receives cancelled as soon as one is successful); Manual receive

Receivable Time Calibration Signals:

Mainflingen, Germany (Call Sign: DCF77, Frequency: 77.5 kHz); Anthorn, England (Call Sign:

MSF, Frequency: 60.0 kHz); Fukushima, Japan (Call Sign: JJY, Frequency: 40.0 kHz); Fukuoka/

Saga, Japan (Call Sign: JJY, Frequency: 60.0 kHz); Fort Collins, Colorado, the United States

(Call Sign: WWVB, Frequency: 60.0 kHz); Shangqiu City, Henan Province, China (Call Sign:

BPC, Frequency: 68.5 kHz)

Compass: 20 seconds continuous reading; North indication by hand; Calibration (bidirectional, northerly); Manual reading

Altimeter:

Measurement range: –700 to 10,000 m (or –2,280 to 32,800 ft.) without reference altitude

Display range: –3,000 to 10,000m (or –9,840 to 32,800 ft.)

Negative values can be caused by readings produced based on a reference altitude or due to atmospheric conditions.

Measurement unit: 10 m (or 40 ft.)

Other: Calibration; Manual reading

E-80

Barometer:

Measurement range: 260 to 1,100 hPa (or 7.7 to 32.5 inHg)

Display unit: 1 hPa (or 0.1 inHg)

Other: Calibration; Manual reading; Barometric pressure differential indicator

Thermometer:

Measurement range: –10.0 to 60°C (or 14 to 140°F)

Measurement unit: 0.1°C (or 1°F)

Other: Calibration; Manual reading

Bearing Sensor Precision:

Direction: Within ±12°

Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).

E-81

Pressure Sensor Precision:

 

Conditions (Altitude)AltimeterBarometer

 

 

± (altitude differential × 2%

 

 

0 to 6000 m

+ 15 m) m

 

 

0 to 19680 ft.

± (altitude differential × 2%

± (pressure differential × 2%

Fixed

 

+ 50 ft.) ft.

+ 2 hPa) hPa

temperature

 

± (altitude differential × 2%

± (pressure differential × 2%

 

6000 to 10000 m

+ 25 m) m

+ 0.059 inHg) inHg

 

19680 to 32800 ft.

± (altitude differential × 2%

 

 

 

+ 90 ft.) ft.

 

Effect of

0 to 6000 m

± 50 m every 10°C

 

0 to 19680 ft.

± 170 ft. every 50°F

± 5 hPa every 10°C

variable

6000 to 10000 m

± 70 m every 10°C

± 0.148 inHg every 50°F

temperature

19680 to 32800 ft.

± 230 ft. every 50°F

 

 

 

Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).

Precision is lessened by strong impact to either the watch or the sensor, and by temperature extremes.

Temperature Sensor Precision:

±2°C (±3.6°F) in range of –10°C to 60°C (14°F to 140°F) Alarm: Daily alarm

Stopwatch:

Measuring unit: 1 second

Measuring capacity: 11:59' 59"

Measuring modes: Elapsed time

Illumination: LED (light-emitting diode); Selectable illumination duration; Auto Light Switch (Full Auto LED Light operates only in the dark)

Other: Power Saving function; Low battery alert (second hand jumping at 2-second intervals); Auto hand position adjustment

Power Supply: Solar panel and one rechargeable battery

Approximate battery operating time: 7 months (from full charge to Level 3) under the following conditions:

Alarm: 10 seconds/day

Light: 1.5 seconds (one operation)/day

Second hand operation: 18 hours/day

Time calibration receive: 4 minutes/day

Direction reading: 20 times/month (20 seconds continuous reading)

Readings using the barometric pressure differential indicator: 12 times/day

Climbs: Once (30 altituded readings)/month

Frequent use of illumination runs down the battery. Particular care is required when using the auto light switch (page E-71).

E-82

E-83

 

 

L-1

City Code Table

 

City CodeCityUTC Offset/

 

GMT Differential

 

 

 

PPG

(PAGO PAGO)

Pago Pago

–11

HNL

(HONOLULU)

Honolulu

–10

ANC

(ANCHORAGE)

Anchorage

–9

LAX

(LOS ANGELES)

Los Angeles

–8

DEN

(DENVER)

Denver

–7

CHI

(CHICAGO)

Chicago

–6

NYC

(NEW YORK)

New York

–5

SCL

(SANTIAGO)

Santiago

–4

RIO

 

Rio De Janeiro

–3

RAI

(PRAIA)

Praia

–1

UTC

 

 

0

LON

(LONDON)

London

 

PAR

(PARIS)

Paris

+1

ATH

(ATHENS)

Athens

+2

JED

(JEDDAH)

Jeddah

+3

THR

(TEHRAN)

Tehran

+3.5

DXB

(DUBAI)

Dubai

+4

KBL

(KABUL)

Kabul

+4.5

KHI

(KARACHI)

Karachi

+5

DEL

(DELHI)

Delhi

+5.5

 

City Code

City

UTC Offset/

 

GMT Differential

 

 

 

KTM

(KATHMANDU)

Kathmandu

+5.75

DAC

(DHAKA)

Dhaka

+6

RGN

(YANGON)

Yangon

+6.5

BKK

(BANGKOK)

Bangkok

+7

HKG

(HONG KONG)

Hong Kong

+8

TYO

(TOKYO)

Tokyo

+9

ADL

(ADELAIDE)

Adelaide

+9.5

SYD

(SYDNEY)

Sydney

+10

NOU

(NOUMEA)

Noumea

+11

WLG

(WELLINGTON)

Wellington

+12

Based on data as of December 2010.

The rules governing global times (UTC offset and GMT differential) and summer time are determined by each individual country.

L-2

L-3