Operation Guide 5242

Calibrating the Barometric Pressure Sensor Reading

The pressure sensor of this watch is adjusted at the factory and so further adjustment is not required by you. However, if you notice that the pressure readings produced by the watch are different from readings produced by another instrument, you can use the procedure in this section to make corrections.

Important!

The watch will not be able to produce correct pressure readings if you make a mistake during the correction procedure. Check to make sure that the value you use for correction produces correct pressure readings.

To calibrate the Barometric Pressure Sensor Reading

1. In the Barometer Mode, loosen the crown and then pull it out.

If the watch is currently performing a barometric pressure reading operation, the hands will move to indicate the current barometric pressure.

 

If the hands do not indicate a barometric pressure, pulling out the

30

crown will take a barometric pressure reading. The z Hour Hand,

30

Example: 1000 hPa

2.Rotate the crown to move the hands so they match the barometric pressure reading produced by another instrument.

Rotating the crown causes the c Second Hand to move in 1 hPa (0.1 inHg) increments.

After you calibrate the barometric pressure sensor reading, you

can clear calibration settings any time by performing step 1 of this procedure and then pressing A and C at the same time. This will cause the hands to move to the result of the last barometric pressure reading the watch performed.

You can toggle the barometric pressure unit between hPa and inHg at this time by holding down C for two seconds.

3.After the setting is the way you want, push the crown back in and then lock it.

For information about the barometric pressure calibration value range, see the barometric pressure display range on page E-53.

x Minute Hand, and c Second hand will indicate the result after

about 10 seconds.

Example: 999 hPa

E-56

Barometric Pressure Reading Precautions

Sudden changes in temperature can affect the pressure sensor and produce errors in reading values.

E-57

Taking Temperature Readings

The Thermometer Mode uses a temperature sensor to take temperature readings. The result of a temperature reading is indicated by the hands of the watch.

Hand Indicators

z Hour Hand: When the unit is Celsius (°C), indicates the 10s digit value. When the unit is Fahrenheit (°F), indicates the 100s digit value.

x Minute Hand: When the unit is Celsius (°C), indicates the 1s digit value. When the unit is Fahrenheit (°F), indicates the 10s digit value.

c Second Hand: When the unit is Celsius (°C), indicates the first digit value to the right of the decimal

point. When the unit is Fahrenheit (°F), indicates the 1s digit value.

v Mode Hand: When the unit is Celsius (°C) and the reading is 0°C or above, points to THERMO °C. When the reading is below 0°C, points to THERMO [–]. When the unit is Fahrenheit (°F), points to THERMO °F.

30

30

To take a temperature reading

1.Enter the Timekeeping Mode.

For information about changing modes, see “Selecting a Mode” (page E-24).

2. Press B twice.

 

The v Mode Hand will move to THERMO °C or THERMO °F.

30

This indicates the currently selected temperature unit setting.

For information about how to change the setting, see “To specify

 

 

altitude, barometric pressure, and temperature units” (page E-62).

The c Second Hand will move to 0 indicating that the temperature reading operation has started. The reading result will appear within eight seconds.

Note

The unit for temperature readings by this watch is 0.1°C (1°F).

The measurement range for temperature readings by this watch is

–10.0°C to 60.0°C (14°F to 140°F).

Whenever a temperature reading is outside the allowable measurement range, the hands of the watches will move to the positions below.

30

z Hour Hand, x Minute Hand, c Second Hand: 11 o’clock

 

v Mode Hand: THERMO °C or THERMO °F

Example: 25.3°C

Example: 62°F

E-58

E-59

Calibrating the Temperature Sensor Reading

The temperature sensor of this watch is adjusted at the factory and so further adjustment is not required by you. However, if you notice that the readings produced by the watch are different from readings produced by another instrument, you can use the procedure in this section to make corrections.

Important!

The watch will not be able to produce correct temperature readings if you make a mistake during the correction procedure. Check to make sure that the value you use for correction produces correct temperature readings.

Before performing the procedure below, remove the watch from your wrist leave it in the area where you will take the reading for about 20 to 30 minutes to allow the case temperature to become the same as surrounding air temperature.

To calibrate the temperature sensor reading

1.In the Thermometer Mode, loosen the crown and then pull it out.

If the watch is currently performing a temperature reading operation, the hands will move to indicate the current temperature.

If the hands do not indicate a temperature, pulling out the crown will take a temperature reading. The hands will indicate the result after about 8 seconds.

2.Rotate the crown to move the hands so they match the temperature reading produced by another instrument.

Rotating the crown causes the c Second Hand to move in 0.1°C (1°F) increments.

After you calibrate the temperature sensor reading, you can clear it any time by performing step 1 of this procedure and then pressing A and C at the same time. This will cause the hands to move to the result of the last temperature reading the watch performed.

You can toggle the temperature unit between Celsius (°C) and Fahrenheit (°F) at this time by holding down C for two seconds.

E-60

30

30

Example: 29.9°C

Example: 30.0°C

3.After the setting is the way you want, push the crown back in and then lock it.

For information about the temperature calibration value range, see the temperature display range on page E-59.

Temperature Reading Precautions

Temperature readings are affected by your body temperature, direct sunlight, and moisture. To achieve a more accurate temperature readings, remove the watch from your wrist, place it in a well ventilated location out of direct sunlight, and wipe all moisture from the case. It takes approximately 20 to 30 minutes for the case of the watch to reach the actual surrounding temperature.

E-61

Specifying Altitude, Barometric Pressure, and Temperature Units

Use the procedure below to specify the altitude, barometric pressure, and temperature units to be used in the Altimeter Mode, Barometer Mode and the Thermometer Mode.

To specify altitude, barometric pressure, and temperature units

1. Make sure the watch is the the mode for the type of unit you want to specify (Altimeter, Barometer, or Thermometer Mode).

For information about changing modes, see “Selecting a Mode”

(page E-24).

2. After loosening the crown, pull it out.

The v Mode Hand will move to the currently selected unit setting.

3. Hold down C for about two seconds to toggle between the available unit settings.

When specifying this type of unit:

Press C to toggle between these settings:

 

 

Altitude

m (meters) and ft (feet)

 

 

Barometric Pressure

hPa (hectopascals) and inHg (inches of mercury)

 

 

Temperature

°C (Celsius) and °F (Fahrenheit)

 

 

4. After the setting is the way you want, push the crown back in and lock it.

Using the Alarm

When the alarm is turned on, an alarm will sound for about 10 seconds each day when the time in the Timekeeping Mode reaches the preset alarm time. This is true even if the watch is not in the Timekeeping Mode.

Hand Indicators

z Hour Hand: Indicates the currently set alarm time hour.

x Minute Hand: Indicates the currently set alarm time minute.

c Second Hand: Indicates the current a.m. (A) and p.m. (P) setting.

v Mode Hand: Indicates the current alarm on (ALM ON) and off (ALM OFF) setting.

30

To change the alarm time setting

1. Use B to select the Alarm Mode (ALM) as shown on page E-24.

The v Mode Hand will move to ALM ON or ALM OFF to indicate the current setting. The c Second Hand indicates the current A (a.m.) or P (p.m.) setting.

2. After loosening the crown, pull it out.

The v Mode Hand will move to ALM ON.

You can toggle between the hour and minute setting mode, and the hour only setting mode by pressing B.

E-62