Connection of the Power Supply Cable

42

Connection of the Power Supply Cable

Unhook the terminal board cover by inserting a screwdriver into the two hooks “A” (fig. 41).

Open the cable gland by unscrewing screw “F” (fig. 42), unscrew the terminal screws and remove the cable.

The new supply cable, of suitable type and section, is connected to the terminal board following the diagram of fig. 43.

A

Fig. 41

F

Fig. 42

Feeder Cable Section

Type H05RR-F

230 V~ 3 x 1.5 mm2

230 V Feeder Cable Section

E

 

 

Earth

 

 

N

 

 

Neutral

L

 

 

Live

LN

E

Fig. 43