Mains Electricity Connection

THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE.

We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.

The wires in the mains lead of this appliance are coloured in accordance with the following code:

BLUE = NEUTRAL, BROWN = LIVE.

As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the terminals connecting to the fused spur, proceed as follows:

The wire which is coloured blue must be connected to the terminal marked N (Neutral), or coloured black.

The wire which is coloured brown must be connected to the terminal marked L (Live), or coloured red.

NOTE: USE A 3A FUSE

DOUBLE POLE SWITCHED

FUSED SPUR OUTLET

USE A 3 AMP FUSE

Assembly and electrical connection should be carried out by competent personnel.

When installing this product we recommend you seek the help of another individual.

IMPORTANT: THIS APPLIANCE IS A CLASS II APPLIANCE (DOUBLE INSULATED) AND IS NOT INTENDED TO BE EARTHED. DO NOT FIT AN EARTH LEAD TO THIS EXTRACTOR.

Do not mount the isolation switch behind the chimney section. It is a requirement that you must be able to isolate the extractor from the mains electrical supply after installation.

This appliance is intended to be connected to the mains electrical supply by means of an isolation switch and fused spur and is intended to be protected by a 3A fuse. The use of a 13A fuse can cause damage to the internal wiring in the event of a fault, and may also invalidate the warranty.

Electrical Information

Mains electrical voltage: 230 – 240Vac.

Total rated power consumption : 150W

Troubleshooting

If your extractor is not working:

1.Check that the mains supply has not been switched off.

2.Check that the fuse in the spur has not blown.

Contact CDA Customer Care

A : Customer Care Department, The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY

T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www.cda.eu

Page 6
Image 6
CDA CIN6 manual Mains Electricity Connection, Electrical Information, Troubleshooting, If your extractor is not working

CIN6 specifications

CDA CIN6, short for Clinical Document Architecture Release 6, is a significant advancement in the standardization of clinical documents within the health informatics landscape. Developed by Health Level Seven International (HL7), CDA CIN6 is designed to improve the interoperability and exchange of clinical data across different healthcare systems. This version of the standard incorporates various features and technologies aimed at enhancing the usability and richness of clinical documentation.

One of the main features of CDA CIN6 is the structured representation of clinical documents. This enables healthcare providers to create, share, and exchange detailed information about patient conditions, treatments, and outcomes in a standardized format, which can be easily interpreted by various electronic health record (EHR) systems. The standard builds on previous versions with added support for rich text formatting, allowing for a more comprehensive representation of clinical narratives. This feature is crucial for preserving the nuances of clinical information while ensuring that the data remains accessible and usable across different platforms.

Another critical technology underpinning CDA CIN6 is its XML-based structure. Extensible Markup Language (XML) allows for machine-readable formatting which makes it easier to validate, parse, and transform clinical documents. This capability is essential for healthcare institutions that aim to integrate CDA documents into their existing information systems, as it supports seamless data exchange and minimizes the risk of information loss during transmission.

CDA CIN6 also emphasizes the use of templates to define specific clinical document types, which can be tailored to meet the unique requirements of various specialties and regions. This templating approach facilitates consistency across documentation practices while enabling customization as needed. The standard is designed to support both human readability and machine processing, ensuring that the information contained within the documents is not only useful for healthcare providers but also for applications like clinical decision support systems.

Moreover, CDA CIN6 embraces the growing trend of patient engagement by incorporating patient-generated data more effectively. The standard allows for the inclusion of data from various sources, including wearable devices and mobile health applications, thereby providing a more holistic view of a patient’s health status. This integration supports better clinical outcomes and fosters a collaborative approach to patient care.

In conclusion, CDA CIN6 is a transformative update that enhances the way clinical documents are created, shared, and utilized in healthcare. With its rich features, XML-based technology, templating support, and emphasis on patient-generated data, CDA CIN6 paves the way for improved interoperability and patient-centered care in today's increasingly data-driven healthcare environment.