Gas Supply Requirements
IMPORTANT: THIS APPLIANCE SHOULD BE FITTED BY A GAS SAFE REGISTERED FITTER OR OTHER SUITABLY QUALIFIED PERSON.
•This installation must comply with the Gas Safety (installation and use) Regulations 1984.
•This appliance is category II2H3+ and is designed for use in the UK and Ireland. The installation must comply with the Gas Safety (installation and use) Regulations 1984.
•The CDA Group Ltd is not legally able to provide any assistance in the installation of gas appliances except to Gas
Safe registered installers. Any Gas Safe registered fitter requiring help must provide their name, address and registration number. Information supplied will be validated before help is provided.
•This appliance is suitable for conversion to Liquid Petroleum Gas (G30 or G31) or for natural gas (G20). A kit is provided. Do not attempt to fit the conversion kit yourself.
•In the event that this appliance is not installed in accordance with the above requirements, the appliance may be disconnected from the mains gas supply until any faults are rectified; this is a legal requirement.
•This appliance should be installed using 15mm copper pipe connected via a
•This appliance must not be connected to a combustion gas recovery scavenging system
•The connection to the gas supply must comply with all current regulations in force.
•We are not legally able to offer advice on the installation of gas appliances to non Gas Safe registered personnel.
Ventilation
All rooms require a window or equivalent (e.g. a door) which can be opened. Some rooms require a permanent vent in addition to a window (see below).
This unit must not be used in a room which is less than 5m3. The following table details the requirements based on the kitchen volume (L x W x H) in m3.
| Room Volume (m3) | Air Vent Required (cm3) |
|
5 | 100 |
| |
|
|
|
|
| 6 to 10 | 50 |
|
| 6 to 11 | No permanent vent required if a door opens to the outside | |
| 11 or more | None required |
The above requirements also allow use of a gas oven and grill but if there are any other fuel burning appliances in the same room, consult the relevant British Standard (BS5440) or Gas Safe document.