Cecilware IC-25A, IC-18A, IC-22A operation manual Control Panel

Models: IC-25A IC-22A IC-18A

1 11
Download 11 pages 58.83 Kb
Page 5
Image 5
Control Panel:

Temperature Hold function: By pressing the “Warm” function key, the Temperature Hold

function will start working. The LED indicates the temperature will hold at 140°F (+/- 5%), push “Warm” function key again, the LED indicates the temperature will hold at 180°F. When the

“Warm” function key is pushed each time, the holding temperature will change as follows: 140°F

-> 180°F -> 285°F -> 360°F -> 430°F -> 140°F ->.

7.With the Temperature Hold function working, the “Warm” indicator light will start flashing. It means the temperature has not yet arrived at the set temperature. When the pan’s temperature arrives the set temperature, the “Warm” indicator light will stay on.

8.To change Temperature Hold function to “Heat” function: Push “Heat” function key, and the function will go back to “Heat” again. Then the rotary control knob will be activated again.

3

2

Control Panel:

7

8

1

5

6

 

4

 

 

1.Power On/ Off Key

2.“Heating” Indicator Light

3.“Heat” Function Indicator Light

4.“Warm”(Hold Temperature) Function Indicator Light

5.“Warm”(Hold Temperature) Function Key

6.“Heat” Function Key

7.Power Level / Holding Temperature Display LED Lights

8.Power Regulator Rotary Knob

Page 5
Image 5
Cecilware IC-25A, IC-18A, IC-22A operation manual Control Panel