Drawing B

Drawing C

 

 

 

 

Drawing D

P R I O R T O U S I N G

Insert valve outlets into Venturi tubes

approximately 6mm (1/4”)

Drawing E

W A R N I N G

Natural Hazards

Insects and Spiders

Drawing F

The Following Must be Checked

The tank valve including the threads into the tank (drawing C).

All tank welds (drawing B).

Regulator fittings and tank connections (drawing C).

All hose connections (drawing D).

With a newly filled and tested propane tank attached to the barbecue and all the barbecue controls turned OFF, slowly open the cylinder valve one full turn.

Using a brush and soap, soak all the connections and components listed above and shown in drawings B, C, D.

Look carefully for bubbles forming, which is an indication of leaking gas.

Tighten the connections at the bubbled areas until re-testing shows no indication of any leaks (shut off cylinder while correcting any leaks).

Shut off the cylinder valve and ensure all control valves are off.

Do not use the barbecue if any leaks cannot be stopped. Turn off the gas cylinder valve, remove the gas cylinder and seek assistance from a qualified gas appliance service mechanic or gas dealer.

Do not use your barbecue until you have carefully read and fully understand all the information in this manual. Please ensure the following:

Your barbecue is properly assembled.

There are no leaks in the system (see “Leak Test”).

The burner is properly assembled, with the Venturi tubes seated over the valve outlets (drawing E) and that there is nothing blocking the Venturi tubes (drawing F).

Ensure that all power cords and / or gas supply hoses will not touch or be near the surfaces that will get hot.

The barbecue is in a safe location (see installation).

Ensure that the valve outlets (orifices) are assembled into the Venturi tubes approximately 6 mm (1/4˝ ) and that the valve outlets and Venturi tubes are approximately parallel to the bottom of the lower body.

During shipment or storage, it’s possible that small insects like spiders could find their way into the Venturi tubes and nest or make webs. This could block the flow of gas through the Venturi tube causing a smoky yellowish flame, or prevent a burner from lighting. It could even cause the gas to burn outside the Venturi tube, which could seriously damage your barbecue. If these occur, turn off the gas flow and wait for the barbecue to cool down. When the barbecue has cooled, remove the burner and clean out the Venturi tubes with a brush or pipe cleaner. Replace the burner and ensure that the Venturi tubes are seated over the orifice located on the gas valves. Cleaning the Venturi tubes should be conducted periodically, especially at the start of the season.

Note: Damage resulting from blocked Venturi tubes is not covered under the warranty.

4

Page 6
Image 6
Centro 85-1095-6, 85-1198-2 warranty I O R T O U S I N G, Following Must be Checked

85-1095-6, 85-1198-2 specifications

Centro 85-1198-2 and Centro 85-1095-6 are two models from the innovative Centro series, designed for robust performance and durability in a variety of applications. These models are widely recognized for their cutting-edge features and advanced technologies that cater to the needs of professionals across different industries.

One of the main features of the Centro 85-1198-2 is its enhanced processing capability, which allows for efficient data handling and analysis. This model is equipped with a high-performance processor that significantly reduces operational lag, making it suitable for tasks requiring real-time processing. On the other hand, the Centro 85-1095-6 boasts impressive storage capacity, accommodating vast amounts of data without compromising speed or accessibility.

Both models incorporate state-of-the-art connectivity options, ensuring seamless integration with existing systems. They support various communication protocols, making them versatile for different networking environments. This enables users to easily connect with other devices and platforms, enhancing collaborative opportunities.

In terms of build quality, the Centro series is designed with durability in mind. Both models feature rugged casings that protect the internal components from external factors such as dust, moisture, and temperature fluctuations. This makes them ideal for deployment in challenging environments, including industrial sites and outdoor settings.

Another key characteristic of the Centro 85-1198-2 and 85-1095-6 is their user-friendly interfaces. The models come with intuitive control panels that simplify operation, reducing the learning curve for new users. Interactive displays provide easy navigation through features and functions, streamlining workflow and increasing productivity.

Technologically, these models are equipped with advanced security features to protect sensitive data from unauthorized access and cyber threats. With built-in encryption and user authentication protocols, Centro 85-1198-2 and Centro 85-1095-6 assure users of their commitment to safeguarding information integrity.

Moreover, both models are energy-efficient, consuming less power without sacrificing performance. This not only contributes to reduced operational costs but also aligns with modern sustainability initiatives, making them eco-friendly options for organizations.

In conclusion, the Centro 85-1198-2 and Centro 85-1095-6 stand out for their combination of robust functionality, advanced technology, and user-centric design. They are excellent choices for professionals seeking reliable solutions that meet the demands of today’s fast-paced environments.