Fig. 6

For Your Safety, Read Before Lighting

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE OPERATION smell all around the appliance area for gas. Be sure to smell

next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL

GAS:

Do not try to light any appliance.

Piezo

 

Do not touch any electrical switch;

do not use any telephone in your building.

Immediately call your gas supplier from a neighbor’s tele- phone.

Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire depart- ment.

C. Use only your hand to push in

 

Clockwise

or turn the gas control knob.

Fig. 7

 

Never use tools. If the knob

 

3

will not push in or turn by hand,

 

2

4

don’t try to repair it. Call a

 

 

qualified service technician.

 

 

Force or attempted repair may

1/IGN

 

cause a fire or an explosion.

 

 

 

D. Do not use this appliance if

 

 

any part of it has been under

Off

 

water. Immediately call a

 

 

qualified service technician to

 

 

inspect the appliance and to

 

 

replace any part of the control system or gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above before proceed- ing.

2.Refer to Figure 7. To turn off the gas supply, depress the

knob slightly and turn clockwise to the OFF position.

3.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don’t smell gas, go to the next step.

4. Refer to Figure 8. Locate the pilot. It is at the right of the front main burner next to the control knob.

5. Refer to Figure 9.

Fig. 8

Push in the control knob

and turn counterclockwise to the 1/IGN position. Hold the control knob in for a few seconds.

6.While still holding in the control knob, press the ignitor push- button several times. This will cause a spark at the pilot which will ignite the pilot gas.

7.Hold the control knob for 20 seconds to prevent the flame failure detector from shutting off the gas while its probe is warming up.

8. Release the control knob.

If the knob does not pop up when released, stop and im- mediately call your service

technician.

 

Counterclockwise

 

If the pilot will not stay lit after

Fig. 9

 

several tries, turn the gas

 

3

 

control knob to OFF and call

4

2

your service technician or gas

 

 

supplier.

 

 

 

9. When the pilot remains lit, turn

1/IGN

 

the control knob counterclock-

 

 

wise

to the setting you

Off

 

prefer.

 

 

 

 

 

10.Refer to the table on Page 5 for setting positions.

11.This appliance is fitted with a transient pilot burner for the sole purpose of safe, momentary ignition of the main burner in conjunction with the piezo ignitor. When in operation with the main burner, it contributes to the base heat release and is turned off by turning the control knob to the OFF position.

12.The control knob should not be left at the ignition setting after the pilot has been ignited.

To Turn OFF Gas to Appliance

Depress the control knob slightly and turn it clockwise to the OFF position. Refer to Figure 7.

Match Lighting

If the pilot cannot be ignited with the piezo, it can be manually lit with the use of a match and lighter rod.

1.Place the match in the holder and light. With the right hand, depress and turn the control knob counterclock-

wise (Fig. 9) to the “IGN” position. Hold in for 20 seconds.

2.Take the lighter rod and lighted match and ignite the pilot

.(Fig. 8)

3.Continue to hold the control knob for an additional 20 sec- onds to ensure pilot is maintained.

4.Proceed with Step 8 in Lighting Instructions.

20008056

13

Page 13
Image 13
CFM UVHK36MN, UVHK29MN, UVHK23MP, UVHK31MP manual Clockwise, Counterclockwise

UVHK29MN, UVHK23MP, UVHK31MP, UVHK36MN specifications

The CFM UVHK series is a line of high-performance and versatile indoor units designed for precise temperature control and energy efficiency. The UVHK36MN, UVHK31MP, UVHK23MP, and UVHK29MN models each boast unique features that make them suitable for various applications, offering both comfort and reliability.

One of the key features of the UVHK series is its advanced inverter technology. This technology allows the units to adjust their compressor speed according to the cooling or heating demand, ensuring optimal energy consumption. As a result, users can enjoy significant energy savings while maintaining comfortable indoor temperatures.

The UVHK36MN model is particularly notable for its high cooling capacity, making it ideal for larger spaces. With a cooling capacity of 36,000 BTUs, it can efficiently manage heat loads in commercial environments or spacious residential areas. It also offers a wide operating range, which means it can perform well even in extreme weather conditions.

In contrast, the UVHK31MP is tailored for medium-sized spaces, with a balanced capacity that offers both cooling and heating options. Its sleek design and quiet operation make it suitable for office installations, where creating a comfortable atmosphere is essential for productivity.

The UVHK23MP is specifically designed for smaller rooms and residential use. This model combines compact size with power, making it perfect for apartments and small houses. With its user-friendly controls and efficient performance, the UVHK23MP offers convenience without sacrificing comfort.

The UVHK29MN strikes a balance between capacity and size, catering to both residential and small commercial applications. Its dual functionality allows for both cooling and heating, making it a practical choice throughout the year.

Across the UVHK series, the units are equipped with advanced filtration systems that purify the air, ensuring a healthier indoor environment. They are also designed for low noise levels, minimizing disturbance to occupants.

In summary, the CFM UVHK36MN, UVHK31MP, UVHK23MP, and UVHK29MN models provide a robust solution for climate control needs. With their inverter technology, energy efficiency, and user-friendly features, these units are ideal for a wide range of applications, ensuring comfort and satisfaction for users.