Positioning Logs

The logs must be positioned ONLY as illustrated in Figures 12, 13 and 14

Position the front log so that the large notch in the underside of the right end of the log fits securely and rests on the sheet metal control cover as shown in Figure 15. The front right end of the log has a ‘V’ shaped notch to touch the back of the right-hand grate bar as shown in Figure 16. The left under- side of the front log has a tab that will fit into mating slot in the ember base. When the log is properly placed, there should be no gap between the right underside of the front log and the top edge of the ember base.

CAUTION: Failure to position these parts as they are described in these instructions will cause improper com- bustion and may result in soot being produced.

Position the rear log so that the notches in the back of the log go around and up against the vertical bars of the grate assembly. Install the rear log behind the log spacer brackets. The bracket in the center of the burner assembly must fit into the hole in the center underside of the back log. (Refer to Figure 17 for proper placement of the rear log.)

Position the top log so that its tongue fits securely into the slot on the top of the rear log and the peg fits into the hole in the top of the front log. The top log, when properly positioned, establishes the correct spacing between the front and rear logs.

The left and right twigs are to be placed into the appropriate notches provided in the front and rear logs as shown. (Figs. 12, 13 and 14)

When using the Charred Oak log set the rear standoff must be cut to allow the rear log to be positioned properly. (Fig. 17)

ENSURE THAT THE LOGS ARE CENTRAL AND VERTICAL AS SEEN FROM THE SIDE. TO PREVENT UNWANTED SOOTING, THE FLAME FROM THE BACK BURNER SHOULD NOT TOUCH ANY LOG.

CAUTION: Proper location is critical. When positioning the log set, make sure that the logs do not interfere with the sides of the fireplace before securing the chassis.

Fireplace Screen

The fireplace screen must be in place when the appliance is operating and unless other provisions for combustion air are made, the screen must have openings for the introduction of combustion air.

Decorative Volcanic Ash

The volcanic ash from the bag provided should be sprinkled over the baseplate in front of and below the main burner. Do not sprinkle this material on the fiber base, around the pilot or on the main burner.

Split Bark Logset

Fig. 12 Split Bark logset position.

WARNING: Failure to position the parts in accordance with this diagram or failure to use only parts specifically ap- proved with this heater, may result in property damage or personal injury. Do not alter the logs!

20008056

15

Page 15
Image 15
CFM UVHK31MP, UVHK29MN, UVHK36MN, UVHK23MP manual Positioning Logs, Split Bark Logset

UVHK29MN, UVHK23MP, UVHK31MP, UVHK36MN specifications

The CFM UVHK series is a line of high-performance and versatile indoor units designed for precise temperature control and energy efficiency. The UVHK36MN, UVHK31MP, UVHK23MP, and UVHK29MN models each boast unique features that make them suitable for various applications, offering both comfort and reliability.

One of the key features of the UVHK series is its advanced inverter technology. This technology allows the units to adjust their compressor speed according to the cooling or heating demand, ensuring optimal energy consumption. As a result, users can enjoy significant energy savings while maintaining comfortable indoor temperatures.

The UVHK36MN model is particularly notable for its high cooling capacity, making it ideal for larger spaces. With a cooling capacity of 36,000 BTUs, it can efficiently manage heat loads in commercial environments or spacious residential areas. It also offers a wide operating range, which means it can perform well even in extreme weather conditions.

In contrast, the UVHK31MP is tailored for medium-sized spaces, with a balanced capacity that offers both cooling and heating options. Its sleek design and quiet operation make it suitable for office installations, where creating a comfortable atmosphere is essential for productivity.

The UVHK23MP is specifically designed for smaller rooms and residential use. This model combines compact size with power, making it perfect for apartments and small houses. With its user-friendly controls and efficient performance, the UVHK23MP offers convenience without sacrificing comfort.

The UVHK29MN strikes a balance between capacity and size, catering to both residential and small commercial applications. Its dual functionality allows for both cooling and heating, making it a practical choice throughout the year.

Across the UVHK series, the units are equipped with advanced filtration systems that purify the air, ensuring a healthier indoor environment. They are also designed for low noise levels, minimizing disturbance to occupants.

In summary, the CFM UVHK36MN, UVHK31MP, UVHK23MP, and UVHK29MN models provide a robust solution for climate control needs. With their inverter technology, energy efficiency, and user-friendly features, these units are ideal for a wide range of applications, ensuring comfort and satisfaction for users.