5
Access
Door
Gap between floor
and bottom of door
must not exceed 6mm.
Safety
Reversing Sensor

The Chamberlain Group, Inc.

One-Piece Door with Track Installation (Cable -USA)

3/3/93

Header
Bracket
Header Sleeve Bracket
Door
Bracket
Straight
Door
Arm
Curved
Door Arm
Trolley
Emergency
Release
Rope & Handle
Rail
Garage
Door
Header
Wall
Safety
Reversing Sensor
CLOSED POSITION
Safety Reversing Sensor
FINISHED CEILING
Support bracket & fastening
hardware is required. See page 17.
Safety
Reversing
Sensor
Gap between floor and bottom
of door must not exceed 6mm.
Header
Wall
Access Door
Header
Sleeve Bracket
Header
Bracket
Door Bracket
Header
Wall
Garage
Door

One-Piece Door without Track

Safety Reversing Sensor
FINISHED CEILING
Support bracket
& fastening
hardware is required.
See page 17.
Safety
Reversing
Sensor
Gap between floor and bottom
of door must not exceed 6mm.
Header
Wall
Access Door
CLOSED POSITION
Header
Sleeve Bracket
Header
Bracket
Trolley
Straight
Door
Arm
Emergency
Release
Rope &
Handle
Door Bracket
Curved
Door
Arm
Header
Wall
Rail
Garage
Door
Chain

One-Piece Door with Track

Access
Door
Gap between floor
and bottom of door
must not exceed 6mm.
Safety
Reversing Sensor
The Chamberlain Group, Inc.One-Piece Door with Track Installation (Cable -USA)3/3/93
Header
Bracket
Header Sleeve Bracket
Door
Bracket
Straight
Door
Arm
Curved
Door Arm
Trolley
Emergency
Release
Rope & Handle
Rail
Garage
Door
Header
Wall
Safety
Reversing Sensor
CLOSED POSITION
114A2845

OFF CENTRE INSTALLATION OF OPENER

In situations where obstruction prevent mounting the

opener centrally, offsetting the opener attachment is

possible within the following range - 1/4 Door width

from centre.

NOTE: Even though it is acceptable practise to off

centre mount the opener, the further off centre the

opener is mounted the more dependent is the door

operation on a good installation. This relates to

correct set-up of opener and track, and correct door

balance.

The installation of the IR Safety Sensor is

recommended for an off centre mount application.

ONE-PIECE DOOR INSTALLATIONS

Generally, a one-piece door does not require

reinforcement. If your door is lightweight, you can

refer to the information relating to sectional doors

in Installation Step 11.

Depending on your door’s construction, you may

need additional mounting hardware for the door

bracket (Step 11).

The gap between the bottom of the garage door

and the floor cannot exceed 6mm. Otherwise, the

safety reverse system may not work properly. See

Adjustment Step 3. The floor or the door should be

repaired.

1
1//44DDoooor
rW
Wiiddt
thh
1/4D
Dooo
or
rWWiiddt
th