Regency FP90 Clearances And Height Requirements, Installation, No Combustibles on Face of Unit

Models: FP90

1 40
Download 40 pages 7.42 Kb
Page 8
Image 8
CLEARANCES AND HEIGHT REQUIREMENTS

INSTALLATION

CLEARANCES AND HEIGHT REQUIREMENTS

INSTALLATION

The FP90 may be placed on or near construction materials. The combustion air kit, fire stop spacer and roof fl ashings (not chase fl ashings) may be placed directly on or against normal construction materials. The chimney requires a minimum 2" (51mm) clearance. A combustible mantle (to a depth of 10", 254mm) may be installed no closer than 18" (457mm) above the warm air vent or 55-1/2" (1410mm) from bottom of unit.

The chimney must be enclosed when installed in or passing through a living area where combustible material or people may come in contact with it. This is important to prevent possible personal injury or fi re hazard.

For any further information, please call your dealer. Special restrictions apply to the front and facing of the fi replace and nearby walls.

WARNING: If insulation is used, do not place the unit against it. Insulation or vapor barriers, if used, must be secured to assure insulation and vapor barriers remain in place and do not affect the required air spaces.

No Combustibles on Face of Unit.

Combustibles May Not Extend to Unit Face.

Do not notch wallboard around standoffs.

WARNING: Do not pack or fill required air spaces with insulation or other material. No material of any kind is allowed in these areas.

NOTES:

1)Do not insulate the chase cavity with blown or fi ll type insulation materials.

2)Local codes may not require fi restopping at the ceiling level for outside chase installations; however, it is recommended for safety and the reduction of heat loss.

3)We recommend that you insulate at least the fi rst fl oor of the chase to prevent heat loss.

4)Some local codes require 1 hour fire rating on one or all sides of fire chases. Check with your local authorities.

Max. 10" (254mm)

No Combustibles on Face of Unit. Depth of Mantel

center line

18" (457mm)

 

 

55-1/2" (1410mm) from bottom of unit

Combustibles May Not Extend to Unit Face.20" (508mm)

18" (457mm)

40" (1016mm)

Clearances to Combustibles

8

FPI FP90 Wood Fireplace

Page 8
Image 8
Regency FP90 installation manual Clearances And Height Requirements, Installation, No Combustibles on Face of Unit