INSTALLATION

DIMENSIONS AND SPECIFICATIONS

TheRegencyisawoodburningfireplacefeaturing aself-containedheat-circulatingsystemandcast- iron doors with large viewing windows. A set of andirons are installed in the fi rebox to properly position the fi re, do not remove them.

Note: Illustrations shown reflect “typical” installationswith nominaldimensions and are for design and framing reference only. Actual installations may vary due to individual design preferences.However,alwaysmaintain minimum clearances to combustible materials and do not violate any specific installation requirements.

The Regency fireplace has been tested and listed by OMNI Test Laboratories, Inc. to ULCS610 Standard for Canada installations. This unit is intended for installation in conventional homes and buildings of conventional construction, not in mobile homes.

This fi replace system is designed for installation in accordance with the National Fire Protection Standard for chimneys, fi replaces and solid fuel burning appliances; NFPA211 and in accordance with codes such as the BOCA Basic National Codes, the Standard Mechanical Code, Uniform Building Codes or applicable local codes.

FAILURE TO USE PARTS MANUFACTUREDBYFPIFIREPLACE PRODUCTS INTERNATIONAL, LTD., OR VARIATIONS IN TECHNIQUES AND CONSTRUCTION MATERIAL DESCRIBED IN THIS MANUAL, MAY CREATE A FIRE HAZARDAND VOID REGENCY’S WARRANTY.

The FP90 main unit consists of the following:

1)The main fi re box and heat exchanger

2)Double doors with ceramic glass

3)Vermiculite side panels and baffl e

4)The insulated outside air duct

5)Hearth Safety Strip

6)1" unit base stand-offs

7)Nailing Strips

INSTALLATION

14- 5/8"13-3/8"

(371mm) (371mm)

50- 1/2" (1283mm)

42- 5/8"

 

(1083mm)

37-3/8"

 

 

(949mm)

 

31"

 

(787mm)

 

29-1/8"

 

(740mm)

 

1-3/8"

 

(35mm)

 

7-7/8"

3-5/8" (92mm)

(200mm)

38"

(965mm)

43- 5/8" (1108mm)

Unit Dimensions

4-3/4"

(121mm)

9-5/8" (244mm)

15"

(381mm)

25" (635mm)

28"

(711mm)

FPI FP90 Wood Fireplace

7

Page 7
Image 7
Regency FP90 installation manual Dimensions and Specifications