INSTALLATION

 

C

 

Metal

3/4"

A

Filler

(19mm)

Strips

2-1/2"

2-1/2"

 

 

(64mm)

(64mm)

 

1-1/4"(32mm)

Stand-off

B

B

Spacers

Non-Combustible

 

 

Material

 

 

 

 

29" (637mm)

 

 

48" (1219mm)

60" (1524mm)

Metal

Filler

Strip

6)Depending on the height of the hearth in front of the unit, it may be necessary to trim the bottom of the mesh sides (B) to fi t. Mark and drill holes for side pieces. Attach with washers and screws.

7)Place the top metal fi ller strip in between stove and framing to cover the stand-off space. Fit the strips behind Top mesh "C" so that it covers the stand-off, and will prevent mortar from falling through the mesh.

8)Put the doors on the unit and check that the veneer on both sides do not interfere with the door swing.

9)Use washers and screw top mesh (C) to top of grill frame. This is attached with the top edge of the grill frame on piece (B).

10)Now fasten mesh to wall sheathing and blend in.

11)Use only non-combustiblemasonry products to fi nish fi replace front.

INSTALLATION

Finishing Details

Consideration must be given to fireplace placement when deciding on how to complete the facing.

IMPORTANT: A tight joint between masonry and fireplace is necessary to prevent heat from rolling up the front to the Face Header.

Example 1:

Face of Fireplace Flush with Wall Framing.

Top View

Example 2:

Face of Fireplace Flush with

Non-Combustible.

Completing The Mantle

A stone mantle may be placed directly above the warm air outlet. If a wood or other combustible mantle is desired, it must be at least 18 inches above the grill opening and may project up to 10" (254mm) in front.

Wire￿Mesh

Stone, Tile￿or￿Brick

Mortar

Heavy Expanded Metal

Non-Combustible

Material

Top View

FPI FP90 Wood Fireplace

19

Page 19
Image 19
Regency FP90 installation manual Finishing Details, Completing The Mantle