FAN INSTALLATION

INSTALLATION

INSTALLATION

FAN INSTALLATION

NOTE: If optional Ashtray is installed, it must be removed before installing the fan.

The receptacle Box must be wired for the fan cable to be plugged into.

1)Remove the thumb screw from the fan transfer tray.

2)Slide fan transfer tray fully out through the bottom louver opening.

3)Mount the fan bracket onto the fan transfer tray using the two locating pins.

4)Slide the Control Box onto the Control Box Mounting Bracket located on the front of the fan transfer tray and secure with

the #8 x 3/8” screw Diagram 1 provided (refer to Diagram 1).

Diagram 1

5)Install the wiring as shown on the wiring diagram. Use the strength relief for running the wires from the fan transfer tray to the receptacle box or the ground screw (refer to Diagram 2).

FAN 910-175

AX-3088910-903910-516

GROUND

POWER CORD 910-519

 

 

NEUTRAL - FROM FAN

SWITCH

 

M

M

VARIABLE

GROUND

 

 

 

910-896

- TO

 

F

F

HOT

 

 

 

 

 

M

 

M

811

 

F

 

F

910-

 

 

 

 

F R

 

F R

 

 

THERMODISC 910-142

VARIABLE SWITCH 910-330

60T12

 

Diagram 2

6)Slide the fan transfer tray back into the unit and hook up wires to the Control Box and mount the thermo disc in place.