Installation Step 6
Install the Multi-Function
Door Control Panel
•Strip 1/4" of insulation from one end of the bell wire; connect the wire to the two screw terminals on the back of the Door Control by color:
white to 2 and white/red to 1.
•Locate the Door Control within sight of the door at a minimum height of 5 feet where small children cannot reach, and away from all moving parts of the door and door hardware. Fasten the
•Run the bell wire up the wall and across the ceiling to the opener. Use insulated staples to secure the wire in several places. Be careful not to pierce the wire with a staple, thereby resulting in a short.
•Receiver terminals and the antenna are located on the right side panel of the opener. Position the antenna wire as shown.
•Then connect the bell wire to the opener terminal screws: white to 2 and white/red to 1.
•Remember to affix the User Safety Instruction label to the wall near the Door Control, and the Maintenance Instruction label in a prominent location on the inside of the garage door.
If the label adhesive will not adhere to your garage wall surface (or becomes loose with time) use tacks to secure the label alongside the Door Control.
Page 28 explains how to operate the opener using the lighted push bar and the Lock & Light features available on the
Hardware Shown Actual Size
6ABx1" Screw
Dry Wall Anchors
Lock Button
Bell Wire
LOCK
LIGHT | Light Button |
|
Door
Control
Button
Door Control Panel
WARNING
Children operating or playing with a garage door opener can injure themselves or others. The garage door could close and cause serious injury or death.
Install the Door Control (or any additional push buttons) out of the reach of children and away from all moving parts of the door and door hardware, but where the garage door is visible. Do not allow children to operate the push button(s) or the remote control transmitter(s).
A moving garage door could injure someone under it. Activate the opener only when the door is properly adjusted, you can see it clearly, and there are no obstructions to door travel.
Do NOT connect the power and operate the opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.
See Safety Reversing Sensor Instructions beginning on page 17.
Outside Keylock Accessory Connections
To opener terminal screws: white to 2; white/red to 1
Door Control Panel
Terminal Screws
RED | WHITE |
| |
- 1 | - 2 |
|
Opener
Terminal
Screws
|
|
| 1 |
| 2 |
|
|
| 3 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 9 |
|
| 1 | 9 | 1 | |
|
|
|
|
|
| 7 |
| 3 | 7 | 3 |
|
|
|
|
|
|
| 5 |
|
| 5 |
| |
|
|
|
|
|
|
| KG |
|
| KG | |
|
|
|
|
| AVERTISSEMENT: Pour réduire les risques de | ||||||
|
|
|
|
| |||||||
|
|
|
|
| blessures mortelles par happement, après tout | ||||||
|
|
|
|
| réglage de la force de déclenchement ou des | ||||||
|
|
|
|
| seuils de fin de course s'assurer que le sens de | ||||||
|
|
|
|
| la course s'inverse lorsque la porte entre en | ||||||
|
|
|
|
| contact avec un object de 13 mm (1 po) de | ||||||
|
|
|
|
| hauteur (ou un madrier de 2 x 4 de section, à | ||||||
|
|
|
|
| plat) posé sur le sol. Effectuer les reglages | ||||||
|
|
|
|
| selon les procédures décrites dans la notice. | ||||||
|
|
|
|
|
|
|
| PART NO: | Nº DE PIÈCE: | ||
|
|
| Sears Roebuck & Co. |
|
|
| D.O.C. CERT. NO. | DATE: | |||
|
|
| Sears Canada Inc., Toronto |
|
|
|
|
|
|
| |
|
|
| Assembled in Mexico - Assemblé du Mexique | M.D.C. CERT. NO. | |||||||
Right Side |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| |||
Panel of |
|
|
|
|
|
|
|
|
| ||
Opener |
| Antenna |
|
|
| ||||||
|
|
|
|
|
|
|
14