Invisible Light Beam
Protection Area
Sensor
Sensor
Connect Wire to
Opener Terminals
Bell Wire
Bell Wire Finished
Ceiling
OPENER TERMINAL SCREWS
Sensor
Connections
Door Control
Connections
(dotted line)
123
19
Figure 6 Wiring the Safety Sensors
1/4"-20x1/2"
Carriage bolt Lens
Wing nut
Figure 5
MOUNTING AND WIRING THE SAFETY SENSORS
• Slide a 1/4"-20x1/2" carriage bolt head into the slot
on each sensor. Use wing nuts to fasten sensors to
brackets, with lenses pointing toward each other
across the door. Be sure the lens is not obstructed
by a bracket extension. See Figure 5.
• Finger tighten the wing nuts.
Run the wires from both sensors to the opener. Use
insulated staples to secure wire to wall and ceiling.
• Strip 1/4" of insulation from each set of wires.
Separate white and white/black wires sufficiently to
connect to the opener terminal screws: white to 2
and white/black to 3.
ALIGNING THE SAFETY SENSORS
Plug in the opener. The indicator lights in both the
sending and receiving eyes will

glow steadily

if
wiring connections and alignment are correct.
The

sending

eye orange indicator light will glow
regardless of alignment or obstruction. If the green
indicator light in the

receiving eye

is off, dim, or
flickering (and the invisible light beam path is not
obstructed), alignment is required.
• Loosen the

sending

eye wing nut and readjust,
aiming directly at the receiving eye. Lock in place.
• Loosen the

receiving

eye wing nut and adjust
sensor until it receives the sender’s beam. When
the green indicator light

glows steadily,

tighten the
wing nut.
TROUBLESHOOTING THE SAFETY SENSORS
1. If the

sending eye

indicator light does not

glow

steadily

after installation, check for:
• Electric power to the opener.
• A short in the white or white/black wires. These
can occur at staples, or at screw terminal
connections.
• Incorrect wiring between sensors and opener.
• A broken wire.
2. If the sending eye indicator light

glows steadily

but
the receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the receiving eye.
3.If the receiving eye indicator light is dim, realign
either sensor.

NOTE: When the invisible beam path is obstructed or

misaligned while the door is closing, the door will

reverse. If the door is already open, it will not close.

The door control will blink 10 times. See page 17.