Installation Step 7
Install the Door Control and Connect all Wiring
Install Door Control
Locate the door control within sight of the door at a minimum height of 5 feet where small children cannot reach, and away from all moving parts of the door and door hardware.
1.Strip 1/4" of insulation from one end of the bell wire and connect it to the two screw terminals on the back of the door control by color: white to 2 and white/red to 1 (see Figure 1).
2.Fasten the Lighted Door Control Button securely with
3.Run the bell wire up the wall and across the ceiling to
the opener. Use insulated staples to secure the wire in several places. Be careful not to pierce the wire with a
staple, creating a short. If your access door is near the garage door, you may run this wire with the Safety
Reversing Sensor wires along the top of the rail. See page 14.
W ARN ING
Children operating or playing with a garage door opener can injure themselves or others. The garage door could close and cause serious injury or death. Install the door control (or any additional push buttons) out of the reach of children and away from all moving parts of the door and door hardware, but where the garage door is visible. Do not allow children to operate the push button(s) or the remote control transmitter(s).
A moving garage door could injure someone under it. Activate the opener only when the door is properly adjusted, you can see it clearly, and there are no obstructions to door travel.
Do NOT connect the power and operate the opener at |
|
| |
this time. | The trolley will travel to the full |
| open |
position but will not return to the | close | position | |
until the sensor beam is connected and properly |
|
| |
aligned. See Step 9 on page 18. |
|
| |
|
|
| |
|
| Door Control Panel | |
| Terminal Screws | ||
| Bell Wire |
|
|
4.Remove the Control Center door on the right panel of the opener to access the terminal screws.
Connect Door Control and Sensor Wiring
5.Thread all wires through the opening at the base of the drive shaft cover (see Figure 2).
6.Insert the remaining wire through the hole in the power
unit and strip 1/4" of insulation from each set of wires.
7.Connect the door control wire to the opener terminal screws: white to 2 and white/red to 1. (See Figure 3.)
8.Separate the sensor white and white/black wires sufficiently to connect to the opener terminal screws: white to 2 and white/black to 3.
9.Attach the User Safety Instruction label to the wall near the door control, and the Maintenance Instruction label in a prominent location on the inside of the garage door.
Page 28 explains how to operate the opener using the door controls and the Lock & Light features available on the
Outside Keylock Connections (see Accessories)
To opener terminal screws: white to 2; white/red to 1
Hardware Shown Actual Size
WHT |
|
2 |
|
RED | Lighted |
1 | |
| Door |
| Control |
| Terminal |
Figure 1 | Screws |
|
To
Sensors
To
Door
Control
Control
Center
Figure 2 | WIRING TO CONTROL CENTER |
RED WHITE | |
1 | 2 |
|
Insert wires through opening in
Drive Shaft Cover
Terminal
Screws
Push wiring
through hole in chassis (above Control Center) and connect to opener
terminal screws
6AB x 1" Screw
Insulated | Dry Wall | |
Lighted Door Control Button | Staples | Anchors |
Door Control | Sensor |
|
Connections | Connections |
|
(dotted line) |
|
|
1 | 2 | 3 |
OPENER TERMINAL SCREWS |
| |
Figure 3 | (In Control Center) |
|
17